First experience with THE AUTOLAP™ SYSTEM: an image-based robotic camera steering device

التفاصيل البيبلوغرافية
العنوان: First experience with THE AUTOLAP™ SYSTEM: an image-based robotic camera steering device
المؤلفون: Paulus Johannes Maria Wijsman, Ivo A. M. J. Broeders, Henk W.R. Schreuder, Hylke J. F. Brenkman, Jelle P. Ruurda, Amir Szold, Antonello Forgione, Esther C. J. Consten, Werner A. Draaisma, Yuval Kaufman, Paul M. Verheijen
المساهمون: Surgery
المصدر: Surgical endoscopy, 32(5), 2560-2566. Springer New York
Surgical Endoscopy, 32(5), 2560. Springer New York
سنة النشر: 2018
مصطلحات موضوعية: Adult, Attitude of Health Personnel, Operative Time, Young Adult, 03 medical and health sciences, 0302 clinical medicine, Robotic Surgical Procedures, Joystick, medicine, Journal Article, Humans, Laparoscopy, Simulation, Aged, Focus (computing), medicine.diagnostic_test, business.industry, User satisfaction, Usability, Middle Aged, medicine.disease, Robotic, Inguinal hernia, Workflow, Camera holder, Autolap (TM), Surgery, Computer-Assisted, 030220 oncology & carcinogenesis, Female, 030211 gastroenterology & hepatology, Surgery, Steering, business, Image based, Active camera control systems
الوصف: Background: Robotic camera holders for endoscopic surgery have been available for 20 years but market penetration is low. The current camera holders are controlled by voice, joystick, eyeball tracking, or head movements, and this type of steering has proven to be successful but excessive disturbance of surgical workflow has blocked widespread introduction. The Autolap™ system (MST, Israel) uses a radically different steering concept based on image analysis. This may improve acceptance by smooth, interactive, and fast steering. These two studies were conducted to prove safe and efficient performance of the core technology. Methods: A total of 66 various laparoscopic procedures were performed with the AutoLap™ by nine experienced surgeons, in two multi-center studies; 41 cholecystectomies, 13 fundoplications including hiatal hernia repair, 4 endometriosis surgeries, 2 inguinal hernia repairs, and 6 (bilateral) salpingo-oophorectomies. The use of the AutoLap™ system was evaluated in terms of safety, image stability, setup and procedural time, accuracy of imaged-based movements, and user satisfaction. Results: Surgical procedures were completed with the AutoLap™ system in 64 cases (97%). The mean overall setup time of the AutoLap™ system was 4 min (04:08 ± 0.10). Procedure times were not prolonged due to the use of the system when compared to literature average. The reported user satisfaction was 3.85 and 3.96 on a scale of 1 to 5 in two studies. More than 90% of the image-based movements were accurate. No system-related adverse events were recorded while using the system. Conclusion: Safe and efficient use of the core technology of the AutoLap™ system was demonstrated with high image stability and good surgeon satisfaction. The results support further clinical studies that will focus on usability, improved ergonomics and additional image-based features.
وصف الملف: image/pdf
اللغة: English
تدمد: 0930-2794
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::536a0bc84e2eaf3f587e6359c6b7a662
https://pure.amc.nl/en/publications/first-experience-with-the-autolap-system-an-imagebased-robotic-camera-steering-device(2c0c07e4-366e-456f-89d3-db03c520be56).html
حقوق: RESTRICTED
رقم الأكسشن: edsair.doi.dedup.....536a0bc84e2eaf3f587e6359c6b7a662
قاعدة البيانات: OpenAIRE