Reference Intervals of Cytokeratin-19 Fragment (CYFRA 21-1) in Healthy Adults in China

التفاصيل البيبلوغرافية
العنوان: Reference Intervals of Cytokeratin-19 Fragment (CYFRA 21-1) in Healthy Adults in China
المؤلفون: Yijie Zheng, Yan Li, Yunhai Dai, Shaoneng Tao, Qing Chen, Qu Wei, Shibiao Sang, Qingru Li, Tingting Wu, Fengchao Wang, Anyou Zhu, Jiaqi Song, Qing Li, Yongliang Ji, Yan Wang
المصدر: Clinical Laboratory. 64
بيانات النشر: Clinical Laboratory Publications, 2018.
سنة النشر: 2018
مصطلحات موضوعية: Adult, 0301 basic medicine, China, Percentile, medicine.medical_specialty, Adolescent, Urinalysis, Cross-sectional study, Renal function, Gastroenterology, General Biochemistry, Genetics and Molecular Biology, Young Adult, 03 medical and health sciences, chemistry.chemical_compound, 0302 clinical medicine, Antigens, Neoplasm, Reference Values, Interquartile range, Internal medicine, Biomarkers, Tumor, medicine, Humans, CYFRA 21-1, Aged, Aged, 80 and over, Keratin-19, Creatinine, medicine.diagnostic_test, business.industry, Reproducibility of Results, Middle Aged, Reference intervals, Cross-Sectional Studies, 030104 developmental biology, chemistry, 030220 oncology & carcinogenesis, business
الوصف: Background The reference intervals for serum cytokeratin-19 fragment (CYFRA 21-1) have not been established in Chinese population. This study aimed to measure serum CYFRA 21-1 levels in healthy Chinese subjects. Methods This cross-sectional, four-center study in two Chinese provinces enrolled participants (aged 18 - 85 years) with normal liver/kidney function and normal results for routine blood tests/urinalysis. Serum CYFRA 211 level was measured by ARCHITECT immunoassay (Abbott Diagnostics). Results The study included 3,366 participants. The median (interquartile range) value for serum CYFRA 21-1 level was 1.38 (1.00 - 1.89) ng/mL and tended to increase with age. The upper limit of the 97.5th percentile was 3.55 ng/mL and tended to increase with age. Serum CYFRA 21-1 median level varied between the four centers from 1.22 (0.89, 1.71) to 1.55 (1.12, 2.18) ng/mL, while the 97.5th percentile varied from 3.24 to 4.09 ng/mL. CYFRA 21-1 level correlated weakly with age and creatinine level. Conclusions These new data can help to establish the 'normal range' of serum CYFRA 21-1 in people in China.
تدمد: 1433-6510
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::54d9bcf29345674b90a209037838d32c
https://doi.org/10.7754/clin.lab.2017.170708
رقم الأكسشن: edsair.doi.dedup.....54d9bcf29345674b90a209037838d32c
قاعدة البيانات: OpenAIRE