Association Between Fibulin-1 and Aortic Augmentation Index in Male Patients with Peripheral Arterial Disease

التفاصيل البيبلوغرافية
العنوان: Association Between Fibulin-1 and Aortic Augmentation Index in Male Patients with Peripheral Arterial Disease
المؤلفون: Kaido Paapstel, Mihkel Zilmer, Jaan Eha, Jaak Kals, Anneli Piir, Kaspar Tootsi
المصدر: European Journal of Vascular and Endovascular Surgery. 51(1):76-82
بيانات النشر: Elsevier BV, 2016.
سنة النشر: 2016
مصطلحات موضوعية: Male, 0301 basic medicine, medicine.medical_specialty, Pathology, Manometry, Enzyme-Linked Immunosorbent Assay, Coronary Artery Disease, Type 2 diabetes, Pulse Wave Analysis, 030204 cardiovascular system & hematology, Coronary artery disease, 03 medical and health sciences, Vascular Stiffness, 0302 clinical medicine, Predictive Value of Tests, Risk Factors, Internal medicine, Peripheral arterial disease, Heart rate, medicine, Humans, Prospective Studies, Pulse wave velocity, Aged, Medicine(all), Fibulin-1, business.industry, Calcium-Binding Proteins, Case-control study, Augmentation index, Middle Aged, Aortic Augmentation Index, Atherosclerosis, medicine.disease, Arterial stiffness, Up-Regulation, 030104 developmental biology, Case-Control Studies, Cardiology, Surgery, Resistin, Cardiology and Cardiovascular Medicine, business, Biomarkers
الوصف: BackgroundFibulin-1 (FBLN-1), a newly identified biomarker for vascular stiffness in type 2 diabetes, may participate in the pathophysiological processes leading to progression of arterial stiffness in atherosclerosis. In the present study, the relationship between FBLN-1 and arterial stiffness was examined in patients with atherosclerosis and in healthy subjects.MethodsThirty-eight patients with peripheral arterial disease (PAD) (age 62.4 ± 9.0 years), 38 patients with coronary artery disease (CAD) (age 64.0 ± 9.5 years), and 30 apparently healthy controls (age 61.1 ± 6.4 years) were studied. Serum FBLN-1, oxidized low density lipoprotein (oxLDL), resistin and plasminogen activator inhibitor-1 (PAI-1) levels were measured using the enzyme linked immunosorbent assay method. The technique of applanation tonometry was used for non-invasive pulse wave analysis and pulse wave velocity assessments.ResultsThe levels of FBLN-1 (PAD = 9.4 [4.9–17.8] vs. CAD = 7.1 [4.8–11.8] vs. controls = 5.6 [4.1–8.4] μg/mL; p = .005), carotid-femoral pulse wave velocity (cf-PWV) (9.8 ± 2.2 vs. 9.5 ± 2.2 vs. 8.3 ± 2.2 m/s; p = .023) and the heart rate corrected augmentation index (AIx@75) (29.4 ± 7.2 vs. 19.2 ± 7.2 vs. 15.4 ± 7.1%; p
تدمد: 1078-5884
DOI: 10.1016/j.ejvs.2015.09.004
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::55af2ca53c3c726febd88f8062a8df39
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....55af2ca53c3c726febd88f8062a8df39
قاعدة البيانات: OpenAIRE
الوصف
تدمد:10785884
DOI:10.1016/j.ejvs.2015.09.004