Radiant glass façade technology: thermal and comfort performance based on experimental monitoring of outdoor test cells

التفاصيل البيبلوغرافية
العنوان: Radiant glass façade technology: thermal and comfort performance based on experimental monitoring of outdoor test cells
المؤلفون: Giuseppe La Ferla, Jaime Roset Calzada, Consolacion Ana Car Acha Roman
المساهمون: Universitat Politècnica de Catalunya. AIEM - Arquitectura, energia i medi ambient
المصدر: UPCommons. Portal del coneixement obert de la UPC
Universitat Politècnica de Catalunya (UPC)
سنة النشر: 2020
مصطلحات موضوعية: Electrically heated glass, Environmental Engineering, Radiant thermal 3 asymmetry, Geography, Planning and Development, 0211 other engineering and technologies, Mechanical engineering, 02 engineering and technology, 010501 environmental sciences, Thermal comfort, 01 natural sciences, Thermal, HVAC, Construcció en vidre, 021108 energy, 0105 earth and related environmental sciences, Civil and Structural Engineering, Temperature control, business.industry, Glass construction, Arquitectura [Àrees temàtiques de la UPC], Building and Construction, Radiant glass façade, Commercial building façade, Heating system, Edificis comercials -- Conservació de l'energia, Environmental science, Façanes -- Aïllament tèrmic, Facade, Curtain wall, business, Aïllament tèrmic, Facades, Commercial buildings--Energy conservation
الوصف: Fully glazed façades on commercial buildings have a significant impact on the thermal comfort of the occupants. Discomfort caused by thermal asymmetry can be addressed with a commercial glass curtain wall equipped with radiant glass (RG) technology. Such a wall acts as a heating system that uses radiant long-wave heat, and is fully integrated into the façade; the thermal performance of a glass curtain wall can be adapted according to occupant requirements.This study presents the results of an experimental campaign of tests conducted in outdoor test cells equipped with RG to assess the thermal and comfort performance of the façade. The study compares two identical cells in the same boundary under winter climate conditions: one (as reference) with a commercial low-e double glass façade and an HVAC heating system, and the other (as prototype) equipped with RG technology working entirely as the heating system. Comparisons between data gathered from outdoor cells were performed to investigate the thermodynamic performance, radiant and thermal asymmetry, operative and air temperatures, standards, and local indoor thermal comfort levels of both façades.This study demonstrated that using RG as a heating device can improve the level of thermal comfort by avoiding radiant asymmetry through a uniform distribution of radiant temperature, even along the perimeter zone in higher-glazed façades not subjected to external climatic conditions. The results suggests that operative and ambient temperatures can be lowered while maintaining thermal comfort.
وصف الملف: application/pdf
اللغة: English
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::5a74cd49c3db5b3b3602e53cd2e60ff2
https://hdl.handle.net/2117/335317
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....5a74cd49c3db5b3b3602e53cd2e60ff2
قاعدة البيانات: OpenAIRE