Percutaneous closure of perimembranous ventricular septal defect using patent ductus arteriosus occluders

التفاصيل البيبلوغرافية
العنوان: Percutaneous closure of perimembranous ventricular septal defect using patent ductus arteriosus occluders
المؤلفون: Hoyoun Won, Hieu Lan Nguyen, Seung Yong Shin, Quang Tan Phan, Hieu Ba Tran, Julian Johny Thottian, Linh Huynh Dinh, Saima Sharmin, Dung Duc Doan, Truong Q. Nguyen, Sang Wook Kim, Wang Soo Lee
المصدر: PLoS ONE
PLoS ONE, Vol 13, Iss 11, p e0206535 (2018)
سنة النشر: 2018
مصطلحات موضوعية: Heart Septal Defects, Ventricular, Male, Percutaneous, Septal Occluder Device, Perimembranous ventricular septal defect, lcsh:Medicine, Blood Pressure, 030204 cardiovascular system & hematology, Vascular Medicine, Diagnostic Radiology, Electrocardiography, 0302 clinical medicine, Postoperative Complications, Ductus arteriosus, Ultrasound Imaging, Medicine and Health Sciences, Morphogenesis, 030212 general & internal medicine, lcsh:Science, Child, Heart septal defect, Multidisciplinary, medicine.diagnostic_test, Radiology and Imaging, Heart, Congenital Heart Defects, Systolic Pressure, medicine.anatomical_structure, Treatment Outcome, Echocardiography, Child, Preschool, Aortic Valve, Engineering and Technology, Female, Patient Safety, Anatomy, Research Article, Biotechnology, medicine.medical_specialty, Adolescent, Heart block, Imaging Techniques, Cardiac Ventricles, Cardiology, Bioengineering, Surgical and Invasive Medical Procedures, Prosthesis Design, Research and Analysis Methods, 03 medical and health sciences, Diagnostic Medicine, medicine, Congenital Disorders, Humans, Birth Defects, business.industry, lcsh:R, Biology and Life Sciences, medicine.disease, Surgery, Blood pressure, Ventricular Septal Defects, Cardiovascular Anatomy, lcsh:Q, Medical Devices and Equipment, business, Follow-Up Studies, Developmental Biology
الوصف: Objectives To assess the safety and efficacy of percutaneous closure of perimembranous ventricular septal defect (PmVSD) using patent ductus arteriosus (PDA) occluders. Background Widespread use of conventional PmVSD closure devices has been limited by unacceptable high rate of complete heart block (CHB). The elegant design of PDA occluders is supposed to ease implantation, increase closure rate and minimize damage to adjacent structures. Thus, PDA occluders may reduce complications, especially the CHB, and offer a good alternative for PmVSD closure. Method From September 2008 to October 2015, patients who underwent attempted percutaneous VSD closure using PDA occluders were included in the study. Patient demographics, echocardiography measurements, procedure details and follow-up data until October 2017 were collected. Results In total, 321 patients with a mean age of 15.5±12.6 years and mean a weight of 33.3±20.5 kg were included in this study. The mean defect size was 4.8±2.1 mm. Implantation was successful in 307 (95.6%) patients. The median follow-up time was 63 months (24 to 108 months). The closure rates were 89.5%, 91.5%, and 99.3% after the procedure 24 hours, 6 months and 2 years, respectively. Major complications occurred in 5 (1.7%) patients during the procedure and follow-up, including persistent CHB in 2 (0.7%) patients and device embolization in 3 (1.0%) patients. No death, disability, or other major complication was detected. Conclusion Percutaneous closure of PmVSD using PDA occluders is feasible, safe and efficacious in selected patients.
تدمد: 1932-6203
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::5eae3ec086e1f0bc97afc35925efc7f6
https://pubmed.ncbi.nlm.nih.gov/30439981
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....5eae3ec086e1f0bc97afc35925efc7f6
قاعدة البيانات: OpenAIRE