Clinical Accuracy of 6 Intraocular Lens Power Calculation Formulas in Elongated Eyes, According to Anterior Chamber Depth

التفاصيل البيبلوغرافية
العنوان: Clinical Accuracy of 6 Intraocular Lens Power Calculation Formulas in Elongated Eyes, According to Anterior Chamber Depth
المؤلفون: Jin Li, Qingwen Yang, Linying Ye, Lei Lin, Enze Liu, Er Mo, Yunhui Yu, An-Peng Pan, Lu Zhang, Jiangtao Wang, Qiuyi Huo
المصدر: American Journal of Ophthalmology. 233:153-162
بيانات النشر: Elsevier BV, 2022.
سنة النشر: 2022
مصطلحات موضوعية: Lenses, Intraocular, Optics and Photonics, Refractive error, Biometry, Phacoemulsification, Anterior Chamber, business.industry, High myopia, Axial length, Refraction, Ocular, medicine.disease, Axial Length, Eye, Ophthalmology, Lens Implantation, Intraocular, medicine, Humans, Intraocular lens power calculation, In patient, Nuclear medicine, business, Retrospective Studies, Mathematics
الوصف: Purpose To investigate the influence of anterior chamber depth (ACD) on the accuracy of the Kane, EVO 2.0, Barrett Universal II (BU II), Olsen, SRK/T, and Haigis formulas in patients with elongated eyes. Design Retrospective case series study. Methods A total of 106 patients (106 eyes) diagnosed with high myopia (axial length ≥26 mm) were enrolled and divided into 3 subgroups according to preoperative ACD. Mean refractive error (ME), mean absolute refractive error (MAE), median absolute refractive error (MedAE), and proportions of eyes within ±0.25 D, ±0.50 D, ±0.75 D, and ±1.00 D were calculated. Results In all patients, the MedAE was lowest for the Kane formula (0.28 D), followed by the BU II (0.34 D). In the shallow ACD subgroup, EVO 2.0 formula produced the lowest MedAE (0.22 D), and the highest proportion of eyes within ±0.25 D (58%); the BU II (0.23 D, 50%) and Kane (0.25 D, 50%) formulas produced similar proportions. In the deep ACD group, the MedAEs of the Haigis and SRK/T formulas (0.68 D and 0.50 D, respectively) were significantly higher than those of the EVO 2.0 (0.37 D), Kane (0.30 D), BU II (0.43 D), and Olsen (0.34 D) formulas (P Conclusions Overall, the Kane and EVO 2.0 formulas had the highest accuracy. EVO 2.0 and BU II formulas are recommended for patients with shallow ACD; the Kane formula is recommended for patients with deep ACD (especially patients with extremely elongated eyes). The SRK/T and Haigis formulas should be avoided as much as possible.
تدمد: 0002-9394
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::5faa6873f9dd02bad5b149731b0ba0cb
https://doi.org/10.1016/j.ajo.2021.07.017
حقوق: CLOSED
رقم الأكسشن: edsair.doi.dedup.....5faa6873f9dd02bad5b149731b0ba0cb
قاعدة البيانات: OpenAIRE