Enumeration of extracellular vesicles by a new improved flow cytometric method is comparable to fluorescence mode nanoparticle tracking analysis

التفاصيل البيبلوغرافية
العنوان: Enumeration of extracellular vesicles by a new improved flow cytometric method is comparable to fluorescence mode nanoparticle tracking analysis
المؤلفون: Agnieszka Siupa, Heather Campbell, Leonardo Pasalic, Michelle J. Henderson, Vivien M. Chen, Rebekka T. Williams
المصدر: Nanomedicine: Nanotechnology, Biology and Medicine. 12:977-986
بيانات النشر: Elsevier BV, 2016.
سنة النشر: 2016
مصطلحات موضوعية: 0301 basic medicine, Biomedical Engineering, Pharmaceutical Science, Medicine (miscellaneous), Nanoparticle tracking analysis, Bioengineering, Nanotechnology, Cell Communication, Biology, Extracellular vesicles, Flow cytometry, Extracellular Vesicles, 03 medical and health sciences, Cell Line, Tumor, Enumeration, medicine, Humans, General Materials Science, Small particles, Fluorescent Dyes, medicine.diagnostic_test, Area of interest, Flow Cytometry, Fluorescence, 030104 developmental biology, Cell Tracking, Biophysics, Nanoparticles, Molecular Medicine, Biomarkers
الوصف: Extracellular vesicles (EVs) play a role in a variety of physiological and pathological processes. However, use of EVs as biomarkers has been hampered by limitations of current detection and enumeration methods. We compared fluorescence-threshold flow cytometry (FT-FC) to nanoparticle tracking analysis (NTA) for enumeration of cell culture-derived EVs. FT-FC and NTA utilising fluorescence mode (F-NTA) enumerated similar numbers of EVs stained with a membrane dye PKH67. Both methods were sufficiently sensitive to detect cell-derived EVs above the background of culture medium. Light scatter NTA (LS-NTA) detected 10-100× more particles than either fluorescence-based method but demonstrated poor specificity. F-NTA appeared to have better sensitivity for100nm vesicles, however, the FT-FC method combined direct enumeration of EVs with high sensitivity and specificity in the100nm range. Due to wider availability and higher degree of automation and standardisation, FT-FC is a reasonable surrogate to F-NTA for quantification of EVs.Extracellular vesicles are small particles, which can act as tools for intercellular communication. One recent area of interest in EVs is their potentials as biomarkers. In this article, the authors investigated and compared fluorescence-threshold flow cytometry (FT-FC) to nanoparticle tracking analysis (NTA) for the detection of EVs and showed that FT- FC method could be more advantageous. This technique should provide a new alternative for the future.
تدمد: 1549-9634
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::656da29c52022cf3682f8917919a7394
https://doi.org/10.1016/j.nano.2015.12.370
حقوق: CLOSED
رقم الأكسشن: edsair.doi.dedup.....656da29c52022cf3682f8917919a7394
قاعدة البيانات: OpenAIRE