Association of the Effectiveness of Eye Drop Self-instillation and Glaucoma Progression

التفاصيل البيبلوغرافية
العنوان: Association of the Effectiveness of Eye Drop Self-instillation and Glaucoma Progression
المؤلفون: Alekya P, Rajanala, Alisa J, Prager, Meghan S, Park, Angelo P, Tanna
المصدر: Journal of Glaucoma. 31:156-159
بيانات النشر: Ovid Technologies (Wolters Kluwer Health), 2022.
سنة النشر: 2022
مصطلحات موضوعية: Ophthalmology, Disease Progression, Humans, Glaucoma, Ocular Hypertension, Ophthalmic Solutions, Intraocular Pressure, Tomography, Optical Coherence, Retrospective Studies
الوصف: Among patients with glaucoma or ocular hypertension, ineffective self-instillation of eye drops was associated with an increased long-term risk of progression or advancement of treatment to incisional surgery.The purpose of this study was to evaluate the association between the efficacy of self-instillation of eye drops and long-term glaucoma outcomes.In a previous study, video recordings of eye drop self-instillation by patients with glaucoma or ocular hypertension were graded as effective or ineffective depending on whether the patient successfully instilled at least 1 drop on the right ocular surface. Glaucomatous progression was then retrospectively defined as retinal nerve fiber layer thinning as measured by either optical coherence tomography, visual field progression, or need for incisional glaucoma surgery as determined by a glaucoma specialist unaware of patient performance in the eye drop instillation study. Subjects with at least 2 follow-up optical coherence tomography or visual field studies were included in the current study.The original study enrolled 119 patients. Sufficient follow-up data were available for 101 patients. Eighty-eight patients (87.1%) were effective in eye drop instillation at baseline. Mean follow-up was 5.1 years, during which time 73 patients (72.3%) had progression or underwent incisional surgery in either eye. A significantly higher proportion of patients in the ineffective group met the criteria for progression or underwent incisional surgery (effective: 68.2%; ineffective: 100%; N=101; P=0.017, Fisher exact test). Kaplan-Meier survival analyses showed a significantly faster time to reaching an endpoint in the ineffective group (N=101; P=0.012, log-rank test). There was no difference in age, baseline intraocular pressure, or baseline retinal nerve fiber layer thickness between the groups.Ineffective self-installation of eye drops was associated with an increased risk of glaucoma progression or treatment advancement to incisional surgery.
تدمد: 1057-0829
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::66b16824774ea465e38fe891a5aec091
https://doi.org/10.1097/ijg.0000000000001982
رقم الأكسشن: edsair.doi.dedup.....66b16824774ea465e38fe891a5aec091