InP-based planar photonic crystals infiltrated with solid polymers and liquid crystals
العنوان: | InP-based planar photonic crystals infiltrated with solid polymers and liquid crystals |
---|---|
المؤلفون: | Heijden, van der, R., Kjellander, B.K.C., Carlstrom, C.F., Snijders, J.A.P., Kicken, H.H.J.E., Heijden, van der, R.W., Bastiaansen, C.W.M., Broer, D.J., Karouta, F., Nötzel, R., Drift, van der, E.W.J.M., Salemink, H.W.M., Braun, P.V., Weiss, S.M. |
المساهمون: | Molecular Biosensing for Med. Diagnostics, Photonics and Semiconductor Nanophysics, Photonic Integration |
المصدر: | Tuning the Optic Response of Photonic Bandgap Structures III, 632205-1/10 STARTPAGE=632205;ENDPAGE=1/10;TITLE=Tuning the Optic Response of Photonic Bandgap Structures III |
بيانات النشر: | SPIE, 2006. |
سنة النشر: | 2006 |
مصطلحات موضوعية: | chemistry.chemical_classification, Capillary pressure, Materials science, Scanning electron microscope, Physics::Optics, Polymer, Crystal, Physics::Fluid Dynamics, Condensed Matter::Soft Condensed Matter, chemistry.chemical_compound, Monomer, chemistry, Polymerization, Liquid crystal, Composite material, Photonic crystal |
الوصف: | The filling is reported of the air holes of an InP-based two-dimensional photonic crystal with solid polymer and with liquid crystal 5CB. The polymer filling is obtained by thermal polymerization of an infiltrated liquid monomer, trimethylolpropane triacrylate. The filling procedure for both the monomer and liquid crystal relies on the capillary action of the liquid inside the ~200 nm diameter and > 2.5 µm deep air holes. The solid polymer infiltration result was directly inspected by cross-sectional scanning electron microscopy. It was observed that the holes are fully filled to the bottom. The photonic crystals were optically characterized by transmission measurements around the 1.5 µm wavelength band both before and after infiltration. The observed high-frequency band edge shifts are consistent with close to 100% filling, for both the polymer and the liquid crystal. No differences were observed for filling under vacuum or ambient, indicating that the air diffuses efficiently through the liquid infiltrates, in agreement with estimates based on the capillary pressure rise. |
اللغة: | English |
URL الوصول: | https://explore.openaire.eu/search/publication?articleId=doi_dedup___::6e3883e00dfcf7c02afcd1666c390e60 https://doi.org/10.1117/12.679358 |
حقوق: | OPEN |
رقم الأكسشن: | edsair.doi.dedup.....6e3883e00dfcf7c02afcd1666c390e60 |
قاعدة البيانات: | OpenAIRE |
الوصف غير متاح. |