Cardiovascular implantable electronic device function and longevity at autopsy: an underestimated resource

التفاصيل البيبلوغرافية
العنوان: Cardiovascular implantable electronic device function and longevity at autopsy: an underestimated resource
المؤلفون: Sunil Sinha, Katie Flickinger, Ronald D. Berger, Gordon F. Tomaselli, John Rickard, Joseph E. Marine, Hugh Calkins, Barbara J. Crain, Alan Cheng
المصدر: Heart Rhythm. 13:1971-1976
بيانات النشر: Elsevier BV, 2016.
سنة النشر: 2016
مصطلحات موضوعية: Pacemaker, Artificial, medicine.medical_specialty, business.industry, Autopsy, Materials testing, 030204 cardiovascular system & hematology, United States, Defibrillators, Implantable, Surgery, 03 medical and health sciences, 0302 clinical medicine, Physiology (medical), Materials Testing, Emergency medicine, Equipment Reuse, medicine, Humans, Functional status, 030212 general & internal medicine, Cardiology and Cardiovascular Medicine, business
الوصف: The feasibility and safety of postmortem cardiovascular implantable electronic device (CIED; pacemaker or defibrillator) retrieval for reuse has been shown. To date, studies indicate a low yield of reusable postmortem CIEDs (17%-30%).The purpose of this study was to test the hypothesis that a higher rate of reusable CIEDs would be identified upon postmortem retrieval when an institutional protocol for systematic and routine acquisition, interrogation, reprogramming, and manufacturer analysis was used.Over a 6-year period, all subjects referred for autopsy underwent concomitant CIED pulse generator retrieval and enrollment in the Johns Hopkins Post-Mortem CIED Registry. CIEDs were interrogated, reprogrammed, and submitted for manufacturer analysis.In total, 84 autopsies had CIEDs (37 pacemakers, 47 implantable cardioverter-defibrillators). CIEDs were implanted 2.84 ± 2.32 years before death, with 30% implanted1 year before death. Overall, CIED postmortem longevity was 4.79 ± 3.41 years, with 56% demonstrating longevity ≥4 years (this group had an estimated mean longevity of 7.37 ± 2.44 years). Manufacturer analyses uncovered 2 falsely triggered elective replacement indication alerts, confirmed 5 correctly triggered elective replacement indication alerts, identified a recalled pacemaker, and verified that a defibrillator had undergone nonprogrammable hard reset.When a protocol for systematic and routine postmortem CIED retrieval, interrogation, reprogramming, and analysis was used, we noted that60% of pacemakers and50% of defibrillators demonstrated normal functional status with projected longevities7 years on average. Formation of a national hospital-based "CIED donor network" would facilitate larger scale charitable efforts in underserved countries.
تدمد: 1547-5271
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::70907bd647629cec84a75e31c3296a0f
https://doi.org/10.1016/j.hrthm.2016.05.023
حقوق: CLOSED
رقم الأكسشن: edsair.doi.dedup.....70907bd647629cec84a75e31c3296a0f
قاعدة البيانات: OpenAIRE