The Effect of Length and Structure of Attached Polyethylene Glycol Chain on Hydrodynamic Radius, and Separation of PEGylated Human Serum Albumin by Chromatography

التفاصيل البيبلوغرافية
العنوان: The Effect of Length and Structure of Attached Polyethylene Glycol Chain on Hydrodynamic Radius, and Separation of PEGylated Human Serum Albumin by Chromatography
المؤلفون: Mahdiyeh Mashahdi-keshtiban, Hamid Reza Heidari, Parvin Akbarzadehlaleh, Mona Mirzaei
المصدر: Advanced Pharmaceutical Bulletin
Advanced Pharmaceutical Bulletin, Vol 11, Iss 4, Pp 728-738 (2021)
سنة النشر: 2020
مصطلحات موضوعية: Hydrodynamic radius, Ion chromatography, Size-exclusion chromatography, Pharmaceutical Science, 02 engineering and technology, Polyethylene glycol, RM1-950, 030226 pharmacology & pharmacy, 03 medical and health sciences, chemistry.chemical_compound, 0302 clinical medicine, PEG-HSA, Size exclusion chromatography, PEGylated, PEG ratio, medicine, General Pharmacology, Toxicology and Pharmaceutics, Chromatography, Chemistry, Elution, PEGylation, Human serum albumin, Ion-exchange chromatography, 021001 nanoscience & nanotechnology, body regions, embryonic structures, Therapeutics. Pharmacology, 0210 nano-technology, medicine.drug, Research Article
الوصف: Purpose: This study focuses on the effect of length and structure of attached polyethylene glycol (PEG) chain on hydrodynamic radius (Rh ) and chromatographic retention of PEGylated protein. To this aim human serum albumin (HSA) as a standard protein was PEGylated site specifically with mPEG-maleimide. Methods: Separated PEG_HSA fractions were analyzed by size exclusion and anion exchange chromatography (AExC). The purity of fractions and the relative mobility of PEGylated and native proteins were analyzed by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE). Hydrodynamic radius was determined based on the retention time of fractions on size exclusion chromatography (SEC), and also according to the previously reported equations. Results: A linear relation was shown between the molecular weight of attached PEG and Rh of PEGylated HSA. No significant difference between Rh of proteins modified with linear and branched PEG was shown. In SDS-PAGE, the delaying effect of branched PEG on movement of PEGylated protein was higher than that of linear PEG. Conclusion: As PEGylated HSA and dimer HSA have almost the same size and in SEC they elute at very close retention times, so in this case ion exchange chromatography (IExC) is more effective than SEC in separation of PEGylated HSA. Branched PEG- HSA showed earlier elution on anion exchange chromatography compared to linear PEG-HSA, that this can explain the different shielding effect of various structures of attached PEGs. The smaller size of PEGylated HSA in compare to the sum of the hydrodynamic radiuses of native HSA and attached PEG could be as a result of shielded attachment of polymer around protein.
تدمد: 2228-5881
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::72b734df18a073432c2f74e2e1f6a350
https://pubmed.ncbi.nlm.nih.gov/34888220
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....72b734df18a073432c2f74e2e1f6a350