مصطلحات موضوعية: Cerium oxide, Cell Survival, Cytotoxicity, Analytical chemistry, Tetrazolium Salts, Nanoparticle, Toxicology, Cell Line, Mammalian cell, Toxicity Tests, Animals, MTT assay, Mammalian cell line, Particle Size, Fish cell line, Inductively coupled plasma mass spectrometry, Chromatography, L-Lactate Dehydrogenase, Chemistry, Cerium, General Medicine, Rats, Thiazoles, Neutral Red, Cell culture, Oncorhynchus mykiss, Particle, Nanoparticles
الوصف: Two cerium oxide nanoparticles (CeO2 NPs) and one micro-sized CeO2 particle were thoroughly characterized in their pristine form, in water and in cell culture medium. The particles were tested for cytotoxicity to the H4IIE rat hepatoma cell line or the RTG-2 rainbow trout gonadal cell line by means of four standard cytotoxicity assays. Nominal concentrations were verified by inductively coupled plasma mass spectrometry (ICP-MS) and methods were assessed for their suitability to detect reliably adverse effects due to particle exposure. All three particles showed aggregation in water and media. In the H4IIE cell line, the MTT cytotoxicity test revealed that negative effects could be observed for the CeO2 NPs after 24h and for all particles after 72h of exposure, making the effects size, concentration and time dependent. No negative effect for the concentrations tested was detected for the remaining three assays and the RTG-2 cell line, making the MTT assay and the H4IIE cell line an appropriate system to assess adverse effects of CeO2 NPs. A verification of the nominal concentration through ICP-MS revealed that there was a discrepancy between nominal and measured concentration depending on concentration and particle tested. Interferences of particles with assays were found to be present and need to be taken into consideration. © 2012 Elsevier Ltd.
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::73d036892a94587fc6706bf1623b4e63
http://hdl.handle.net/20.500.12792/3889
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....73d036892a94587fc6706bf1623b4e63
قاعدة البيانات: OpenAIRE