Radiographic Outcomes of Volar Locked Plating for Distal Radius Fractures

التفاصيل البيبلوغرافية
العنوان: Radiographic Outcomes of Volar Locked Plating for Distal Radius Fractures
المؤلفون: Elizabeth Koehler, Ian R. Byram, Jeffry T. Watson, Megan E. Mignemi, Kang-Hsien Fan, Carmen C. Wolfe, Donald H. Lee, Martin I. Jordanov, John J. Block, Douglas R. Weikert
المصدر: The Journal of Hand Surgery. 38:40-48
بيانات النشر: Elsevier BV, 2013.
سنة النشر: 2013
مصطلحات موضوعية: Adult, Male, Wrist Joint, medicine.medical_specialty, Adolescent, Intra-Articular Fractures, Radiography, Locked plating, Article, Fracture Fixation, Internal, Young Adult, Fracture fixation, Bone plate, Humans, Medicine, Orthopedics and Sports Medicine, Aged, Retrospective Studies, Orthodontics, business.industry, Small sample, Radius, Middle Aged, Surgery, body regions, Logistic Models, Treatment Outcome, Tilt (optics), Female, Radius Fractures, business, Bone Plates, Single plate
الوصف: Purpose To assess the ability of volar locked plating to achieve and maintain normal radiographic parameters for articular stepoff, volar tilt, radial inclination, ulnar variance, and radial height in distal radius fractures. Methods We performed a retrospective review of 185 distal radius fractures that underwent volar locked plating with a single plate design over a 5-year period. We reviewed radiographs and recorded measurements for volar tilt, radial inclination, ulnar variance, radial height, and articular stepoff. We used logistic regression to determine the association between return to radiographic standard norms and fracture type. Results At the first and final postoperative follow-up visits, we observed articular congruence less than 2 mm in 92% of fractures at both times. Normal volar tilt (11°) was restored in 46% at the first follow-up and 48% at the final one. Radial inclination (22°) was achieved in 44% at the first follow-up and 43% at the final one, and ulnar variance (01 ± 2 mm) was achieved in 53% at the first follow-up and 53% at the final one. In addition, radial height (14 ± 1mm) was restored in 14% at the first follow-up and 12% at the final one. More complex, intra-articular fractures (AO class B and C and Frykman types 3, 4, 7, and 8) were less likely to be restored to normal radiographic parameters. However, because of the small sample size for some fracture types, it was difficult to discover significant associations between fracture type and radiographic outcome. Conclusions Volar locked plating for distal radius fractures achieved articular stepoff less than 2 mm in most fractures but only restored and maintained normal radiographic measurements for volar tilt, radial inclination, and ulnar variance in 50% of fractures. The ability of volar locked plating to restore and maintain ulnar variance and volar tilt decreased with more complex intra-articular fracture types. Type of study/level of evidence Therapeutic IV.
تدمد: 0363-5023
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::7b4456fc98d42138e283d777d09b074f
https://doi.org/10.1016/j.jhsa.2012.10.007
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....7b4456fc98d42138e283d777d09b074f
قاعدة البيانات: OpenAIRE