Cavity Designs for the CH3 to CH11 of the Superconducting Heavy Ion Accelerator HELIAC

التفاصيل البيبلوغرافية
العنوان: Cavity Designs for the CH3 to CH11 of the Superconducting Heavy Ion Accelerator HELIAC
المؤلفون: Conrad, Thorsten, Aulenbacher, Kurt, Barth, Winfried, Basten, Markus, Busch, Marco, Dziuba, Florian, Gettmann, Viktor, Heilmann, Manuel, Kürzeder, Thorsten, Lauber, Simon, List, Julian, Miski-Oglu, Maksym, Podlech, Holger, Rubin, Anna, Schnase, Alexander, Schwarz, Malte, Yaramyshev, Stepan
المصدر: JACoW Publishing, Geneva, Switzerland 396-398 (2019). doi:10.18429/JACOW-SRF2019-TUP005
Proceedings of the 19th International Conference on RF Superconductivity
Proceedings of the 19th International Conference on RF SuperconductivityThe 19th International Conference on RF Superconductivity, Dresden, Germany, 2019-06-30-2019-07-05
بيانات النشر: JACoW Publishing, Geneva, Switzerland, 2022.
سنة النشر: 2022
مصطلحات موضوعية: Cavities - Design, Cavities, Accelerator Physics
الوصف: Proceedings of the 19th International Conference on RF Superconductivity The 19th International Conference on RF Superconductivity, Dresden, Germany, 30 Jun 2019 - 5 Jul 2019; JACoW Publishing, Geneva, Switzerland 396-398 (2019). doi:10.18429/JACOW-SRF2019-TUP005
In collaboration of GSI, HIM and Goethe University Frankfurt new designs for the CH-DTL cavities of the proposed Helmholtz Linear Accelerator (HELIAC) are developed. The cw-mode operated linac with a final energy of 7.3 MeV/u is intended for various experiments, especially with heavy ions at energies near the coulomb barrier. Currently twelve superconducting CH-cavities are considered which will be split into four different cryostats. Each cavity will be equipped with dynamic bellow tuners. After successful beam tests with CH⁰ as well as last surface preparations and ongoing rf tests with CH1 and CH2, CH3 to CH11 will be designed. Based on the successful test results, individual optimizations are carried out on the cavity design. Attention was paid to reduce production costs, for example by keeping the cavity diameter in each cryostat constant despite varying particle velocities and gap numbers. In addition to reaching the resonance frequency of 216.816 MHz and the influence of the bellow tuners on the frequency, the mechanical stability of the bellow tuners, the thermal effects on the cavity and the measures to mitigate secondary electron emission are investigated.
Published by JACoW Publishing, Geneva, Switzerland
اللغة: English
DOI: 10.18429/jacow-srf2021-supcav006
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::7de9e725d2c1a6f3abf00bd1ee946fc8
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....7de9e725d2c1a6f3abf00bd1ee946fc8
قاعدة البيانات: OpenAIRE
الوصف
DOI:10.18429/jacow-srf2021-supcav006