Retrograde Intubation Over a Flexible Fiber-Optic Bronchoscope

التفاصيل البيبلوغرافية
العنوان: Retrograde Intubation Over a Flexible Fiber-Optic Bronchoscope
المؤلفون: Ramanjot S. Kang, Robert Hutnik, Ishu Kant, Aaron Zlatopolsky, Chamandeep Brar, Slawomir P. Oleszak
المصدر: Anesth Prog
بيانات النشر: American Dental Society of Anesthisiology, 2022.
سنة النشر: 2022
مصطلحات موضوعية: Adult, Young Adult, Anesthesiology and Pain Medicine, Bronchoscopes, Tracheostomy, Bronchoscopy, Intubation, Intratracheal, Fiber Optic Technology, Humans, Case Report
الوصف: Traditional retrograde intubation consists of tracheal intubation performed over a guide wire inserted into the trachea inferior to the vocal cords and then passed transorally or transnasally. This intubation technique is reserved for patients with a difficult airway when other methods such as blind nasal intubation or video laryngoscopy fail. A guide wire passed blindly in a retrograde fashion, however, is not without its own constraints. This case report presents the anesthetic management of a 23-year-old Duchenne muscular dystrophy patient with substantial scarring from a previous tracheostomy stoma and limited mouth opening. The patient underwent a retrograde fiber-optic transnasal intubation without the use of a guide wire for a tracheostomy revision procedure, followed by a second tracheostomy revision and retrograde fiber-optic transoral intubation 7.5 months later. This report demonstrates a novel technique for intubating patients with difficult airways. The use of a flexible fiber-optic bronchoscope for a retrograde intubation mitigates complications that can arise using traditional retrograde intubation over a guide wire and increases the likelihood of successful intubation.
اللغة: English
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::82ceae2207b3bc42e1e00d357c6cc75c
https://europepmc.org/articles/PMC8985462/
حقوق: OPEN