A new method for depth of interaction determination in PET detectors

التفاصيل البيبلوغرافية
العنوان: A new method for depth of interaction determination in PET detectors
المؤلفون: Zile Liu, T. Niknejad, M. Pizzichemi, Marco Paganoni, Joao Varela, G. Stringhini, Stefaan Tavernier, Etiennette Auffray, Paul Lecoq
المساهمون: Pizzichemi, M, Stringhini, G, Niknejad, T, Liu, Z, Lecoq, P, Tavernier, S, Varela, J, Paganoni, M, Auffray, E, Physics, Elementary Particle Physics
بيانات النشر: Institute of Physics Publishing, 2016.
سنة النشر: 2016
مصطلحات موضوعية: Radiology, Nuclear Medicine and Imaging, Tomography Scanners, X-Ray Computed, positron emission tomography, Physics::Instrumentation and Detectors, SiPM, Physics::Medical Physics, LYSO, depth of interaction, Scintillator, 01 natural sciences, Lyso, 030218 nuclear medicine & medical imaging, 03 medical and health sciences, 0302 clinical medicine, Optics, Silicon photomultiplier, 0103 physical sciences, Physics, Photons, Scintillation, Radiological and Ultrasound Technology, 010308 nuclear & particles physics, business.industry, Attenuation, Detector, Resolution (electron density), Scintillation counter, Scintillation Counting, Tomography, X-Ray Computed, business
الوصف: A new method for obtaining depth of interaction (DOI) information in PET detectors is presented in this study, based on sharing and redirection of scintillation light among multiple detectors, together with attenuation of light over the length of the crystals. The aim is to obtain continuous DOI encoding with single side readout, and at the same time without the need for one-to-one coupling between scintillators and detectors, allowing the development of a PET scanner with good spatial, energy and timing resolutions while keeping the complexity of the system low. A prototype module has been produced and characterized to test the proposed method, coupling a LYSO scintillator matrix to a commercial SiPMs array. Excellent crystal separation is obtained for all the scintillators in the array, light loss due to depolishing is found to be negligible, energy resolution is shown to be on average 12.7% FWHM. The mean DOI resolution achieved is 4.1 mm FWHM on a 15 mm long crystal and preliminary coincidence time resolution was estimated in 353 ps FWHM. A new method for depth of interaction determination in PET detectors (PDF Download Available). Available from: https://www.researchgate.net/publication/303741851_A_new_method_for_depth_of_interaction_determination_in_PET_detectors [accessed Mar 06 2018].
اللغة: English
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::84c9253274174176bd829ae185588aa0
http://hdl.handle.net/10281/122831
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....84c9253274174176bd829ae185588aa0
قاعدة البيانات: OpenAIRE