European semi-anthropomorphic phantom for the cross-calibration of peripheral bone densitometers: assessment of precision accuracy and stability

التفاصيل البيبلوغرافية
العنوان: European semi-anthropomorphic phantom for the cross-calibration of peripheral bone densitometers: assessment of precision accuracy and stability
المؤلفون: R.D. Hesch, J. Bright, C. Reiners, R. Jonson, P. Schneider, Piet Geusens, P Jaeger, J. Pearson, Heikki Kröger, J. C. Birkenhager, Judith E. Adams, A. M. Laval-Jeantet, Peter Rüegsegger, M. Fischer, Jan Dequeker, A. van Lingen, A. Mitchell, Dieter Felsenberg, M. Henley, J. Reeve, Willi A. Kalender, Lars Hyldstrup
سنة النشر: 2016
مصطلحات موضوعية: Quality Control, Accuracy and precision, Computer science, Context (language use), Biochemistry, Imaging phantom, Absorptiometry, Photon, Endocrinology, Bone Density, Calibration, medicine, Humans, Densitometer, Quantitative computed tomography, medicine.diagnostic_test, Epoxy Resins, business.industry, Reproducibility of Results, Reference Standards, Europe, Models, Structural, Forearm, Durapatite, Regression Analysis, Surgery, Tomography, Tomography, X-Ray Computed, Nuclear medicine, business, Densitometry, Algorithm
الوصف: A semi-anthropomorphic 'distal radius like' phantom, developed by Kalender and Ruegsegger for use in peripheral bone densitometry using single photon (DPA) dual X-ray (DXA) and quantitative computed tomography (QCT) machines, has been studied with a view to cross-calibrating different types and brands of densitometers in current use. In the context of an EU 'Concerted Action' (second Framework Programme) the phantom was repeatedly measured on six SPA machines, three DXA machines and nine QCT machines (545 measurements). Linear regression equations were derived, individual to each machine, which allowed the derivation of 'standardized densities'. In this way we converted measurements made by machines of the same modality to a common scale of measurements. Two machines (one DXA, one SPA) showed statistically significant instability over time emphasising the need for rigorous quality control in the application of densitometry. In other respects these results provide an encouraging basis for the derivation of standardized normative ranges and the more effective use of peripheral densitometry in future clinical and epidemiological studies.
اللغة: English
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::89b9dbc1b7812ca1d4d9164533e58512
https://doi.org/10.1016/s0169-6009(08)80213-9
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....89b9dbc1b7812ca1d4d9164533e58512
قاعدة البيانات: OpenAIRE