Customized Cochlear Implant Positioning in a Patient With a Low- Grade Glioma: Towards the Best MRI Artifact Management

التفاصيل البيبلوغرافية
العنوان: Customized Cochlear Implant Positioning in a Patient With a Low- Grade Glioma: Towards the Best MRI Artifact Management
المؤلفون: Pietro Canzi, Sabino Luzzi, Elena Carlotto, Anna Simoncelli, Natascia Brondino, Stefania Marconi, Marianna Magnetto, Giotta A. Lucifero, Irene Avato, Marco Manfrin, Ferdinando Auricchio, Lorenzo Preda, Marco Benazzo
المصدر: Otology & Neurotology. 43:e628-e634
بيانات النشر: Ovid Technologies (Wolters Kluwer Health), 2022.
سنة النشر: 2022
مصطلحات موضوعية: Adult, Male, Young Adult, Cochlear Implants, Otorhinolaryngology, Humans, Glioma, Neurology (clinical), Artifacts, Cochlear Implantation, Magnetic Resonance Imaging, Sensory Systems, Retrospective Studies
الوصف: To report the personalized decision-making pro- cess adopted for a cochlear implant (CI) candidate requiring magnetic resonance imaging (MRI) brain surveillance.Clinical capsule report.Tertiary academic referral center.A 23-year-old man affected by posttraumatic bilat- eral profound hearing loss, already in radiological follow-up for a suspected small left cuneal low-grade glioma.A multidisciplinary approach involving preoperative MRI simulations and 3D printed (3DP) models aiming to adapt the CI position to facilitate MRI brain lesion visibility.MRI visibility and surgical approach.Preoperative MRI scans with the placement of an Ultra 3D CI were performed simulating different implant location to assess the brain lesion visibility in MRI. CI was positioned 9 cm away from the external auditory canal with an angle of 90 degrees. To assess the technical feasibility of the surgical procedure, a patient-specific 3DP head model was produced preoperatively. The postoperative course was uneventful, the patient showed a significant benefit from CI, and the brain lesion was highly visible at the MRI follow-up.The employment of strategies aimed at improving the MRI quality in CI recipients still represents a topic requiring attention. Thanks to multidisciplinary team collaboration, in our case, the CI position was successfully determined to allow unhindered MRI visibility of a specific intracranial structure.
تدمد: 1537-4505
1531-7129
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::8a2ff55ce72f48c1cb922ed7653c915e
https://doi.org/10.1097/mao.0000000000003532
رقم الأكسشن: edsair.doi.dedup.....8a2ff55ce72f48c1cb922ed7653c915e
قاعدة البيانات: OpenAIRE