Implantation of a newly developed direct optic nerve electrode device for artificial vision in rabbits

التفاصيل البيبلوغرافية
العنوان: Implantation of a newly developed direct optic nerve electrode device for artificial vision in rabbits
المؤلفون: Motohiro Kamei, Kentaro Nishida, Hirokazu Sakaguchi, Yasuo Terasawa, Kohji Nishida, Takashi Fujikado, Motoki Ozawa
المصدر: Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs. 15(3)
سنة النشر: 2012
مصطلحات موضوعية: Materials science, genetic structures, medicine.medical_treatment, Forceps, Biomedical Engineering, Medicine (miscellaneous), Vitrectomy, Biomaterials, chemistry.chemical_compound, Silicone, Artificial vision, medicine, Animals, Vision, Ocular, Visual Cortex, Optic Nerve, eye diseases, Electric Stimulation, Electrodes, Implanted, medicine.anatomical_structure, chemistry, Electrode, Optic nerve, Evoked Potentials, Visual, sense organs, Implant, Rabbits, Cardiology and Cardiovascular Medicine, Biomedical engineering, Optic disc
الوصف: The purpose of this study was to investigate the surgical procedures involved in the implantation of a newly developed direct optic nerve electrode device for inducing artificial vision. The electrode device comprised seven wire stimulation electrodes and a return electrode (diameter 50 μm), one manipulation rod (diameter 100 μm), and a cylindrical silicone board (diameter 2.0 mm). The stimulation electrodes and the manipulation rod protruded through the board to allow implantation of the electrode tips into the optic disc of the rabbit eye. The surgical procedures required to insert the device into the vitreous cavity and implant the device into the optic disc were evaluated. When the electrodes were stimulated, electrically evoked potentials (EEPs) were recorded at the visual cortex. The electrode device was inserted into the vitreous cavity with no damage using a trocar through a scleral incision. The device was easily manipulated using vitreoretinal forceps in the vitreous cavity, and the electrode tips were implanted into the optic disc in a single insertion after vitrectomy. When electrical stimulation was applied, EEPs were recorded from all electrode pairs. The newly developed electrode device was inserted into the eye and implanted into the optic nerve disc smoothly and safely, suggesting that these surgical procedures are useful for our artificial vision system.
تدمد: 1619-0904
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::8a9774789bd82dfd0db1ad2c3c55ecce
https://pubmed.ncbi.nlm.nih.gov/22484492
حقوق: CLOSED
رقم الأكسشن: edsair.doi.dedup.....8a9774789bd82dfd0db1ad2c3c55ecce
قاعدة البيانات: OpenAIRE