PENGARUH REGENERASI KOLOM ALUMINA ASAM TERHADAP RECOVERY DAN KUALITAS 99mTc HASIL EKSTRAKSI PELARUT MEK DARI 99Mo HASIL AKTIVASI NEUTRON

التفاصيل البيبلوغرافية
العنوان: PENGARUH REGENERASI KOLOM ALUMINA ASAM TERHADAP RECOVERY DAN KUALITAS 99mTc HASIL EKSTRAKSI PELARUT MEK DARI 99Mo HASIL AKTIVASI NEUTRON
المؤلفون: Widyastuti W, Adang H G, Yono S
المصدر: Urania, Vol 22, Iss 3 (2017)
بيانات النشر: Pusat Teknologi Bahan Bakar Nuklir, 2017.
سنة النشر: 2017
مصطلحات موضوعية: lcsh:T, lcsh:Nuclear engineering. Atomic power, lcsh:Electrical engineering. Electronics. Nuclear engineering, lcsh:Technology, lcsh:TK1-9971, lcsh:TK9001-9401
الوصف: PENGARUH REGENERASI KOLOM ALUMINA ASAM TERHADAP RECOVERY DAN KUALITAS 99m Tc HASIL EKSTRAKSI PELARUT MEK DARI 99 Mo HASIL AKTIVASI NEUTRON. Melalui kerjasama antara PTRR-BATAN, Chiyoda dan JAEA Jepang telah dilakukan pemurnian 99m Tc dari 99 Mo hasil aktivasi neutron dengan menggunakan metode kromatografi kolom alumina asam terhadap hasil ekstraksi MEK (Metil Etil Keton). Pemurnian 99m Tc dengan metode kolom alumina asam hanya dapat digunakan satu kali dan pemurnian berikutnya harus diganti dengan kolom baru. Hal ini dinilai kurang praktis dan juga memerlukan biaya yang mahal. Dalam penelitian ini dicoba penggunaan kolom alumina asam untuk pemurnian 99m Tc lebih dari satu kali dengan melakukan proses regenerasi dengan cara melewatkan larutan HNO 3 0,1N setiap kali proses pemurnian selesai. Penelitian ini bertujuan untuk mendapatkan larutan 99m Tc yang dapat digunakan untuk penandaan kit radiofarmaka. Parameter yang diamati dalam penelitian ini adalah recovery, profil elusi, pH, kemurnian radiokimia dan kemurnian radionuklida (lolosan 99 Mo). Hasil penelitian yang dilakukan selama 5 hari telah diperoleh pH ~5, recovery > 60 %, kemurnian radiokimia > 95 % dan lolosan 99 Mo tidak terdeteksi. Dari hasil perlakuan terhadap kolom alumina asam dengan larutan HNO 3 0,1 N disimpulkan bahwa kolom alumina asam tidak perlu diganti setiap hari. Kata kunci : 99m Tc, 99 Mo, MEK, kolom alumina asam, kemurnian radiokimia. ABSTRACT Purification of 99m Tc from 99 Mo activation using acidic alumina column chromatography system from MEK (Methyl Ethyl Keton) extraction has been carried out through cooperation between PTRR - BATAN, Chiyoda and JAEA Japan. This method has a limitation that acidic alumina column for purification of 99m Tc can be used only once, for the next purification acidic alumina column should be replaced with new column, so it is less practical and also requires high cost. This study aims to obtain a 99m Tc solution can be use for labelling of a radiopharmaceutical kit. In this study, the used of acidic alumina column for 99m Tc purification was tried more than once by regeneration using 0.1N HNO 3 solution after purification process is completed. Parameters observed in this study are the percent recovery, elution profile, pH, radiochemical purity and radionuclida purity. The results of observational studies conducted over 5 days has been obtained pH ~ 5,% recovery > 60%, radiochemical purity of > 95% and 99 Mo leakage not detected. The treatment of acidic alumina column with 0,1 N HNO 3 solution concluded that acidic alumina column does not need to be replaced every day . Keywords : 99m Tc, 99 Mo, MEK, acidic alumina column, radiochemical purity .
اللغة: English
تدمد: 2528-0473
0852-4777
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::8acae27dbbf6e1b5e36a6b0d2067cf75
http://jurnal.batan.go.id/index.php/urania/article/view/3186
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....8acae27dbbf6e1b5e36a6b0d2067cf75
قاعدة البيانات: OpenAIRE