Evaluation of lead isotope compositions of NIST NBS 981 measured by thermal ionization mass spectrometer and multiple-collector inductively coupled plasma mass spectrometer

التفاصيل البيبلوغرافية
العنوان: Evaluation of lead isotope compositions of NIST NBS 981 measured by thermal ionization mass spectrometer and multiple-collector inductively coupled plasma mass spectrometer
المؤلفون: Peng Liang, Kaiyun Chen, Xu Liu, Zhian Bao, Shaocong Lai, Chunlei Zong, Cheng Cheng, Wenting Yuan, Honglin Yuan, Mengning Dai
المصدر: Solid Earth Sciences, Vol 1, Iss 2, Pp 74-78 (2016)
بيانات النشر: Elsevier BV, 2016.
سنة النشر: 2016
مصطلحات موضوعية: Analytical chemistry, Thermal ionization, Multiple-collector inductively coupled plasma mass spectrometer, NIST NBS 981, 010502 geochemistry & geophysics, Mass spectrometry, 01 natural sciences, GeoReM, External reference, Geochemistry and Petrology, Thermal ionization mass spectrometer, Inductively coupled plasma mass spectrometry, 0105 earth and related environmental sciences, Earth-Surface Processes, Isotope analysis, Isotope, Chemistry, lcsh:QE1-996.5, 010401 analytical chemistry, Lead isotope, Geology, Geotechnical Engineering and Engineering Geology, 0104 chemical sciences, lcsh:Geology, Geophysics, NIST, Inductively coupled plasma
الوصف: Because Pb isotopes can be used for tracing, they are widely used in many disciplines. The detection and analysis of Pb isotopes of bulk samples are usually conducted using thermal ionization mass spectrometer (TIMS) and multiple-collector inductively coupled plasma mass spectrometer (MC-ICP-MS), both of which need external reference materials with known isotopic compositions to correct for the mass discrimination effect produced during analysis. NIST NBS 981 is the most widely used reference material for Pb isotope analysis; however, the isotopic compositions reported by various analytical laboratories, especially those using TIMS, vary from each other. In this study, we statistically evaluated 229 reported TIMS analysis values collected by GeoReM in the last 30 years, 176 reported MC-ICP-MS analysis values, and 938 MC-ICP-MS analysis results from our laboratory in the last five years. After careful investigation, only 40 TIMS results were found to have double or triple spikes. The ratios of the overall weighted averages, 206 Pb/ 204 Pb, 207 Pb/ 204 Pb, and 208 Pb/ 204 Pb, obtained from 40 spiked TIMS reports and 1114 MC-ICP-MS results of NIST NBS 981 isotopes were 16.9406 ± 0.0003 (2s), 15.4957 ± 0.0002 (2s), and 36.7184 ± 0.0007 (2s), respectively.
تدمد: 2451-912X
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::996ed1eb40f3006b120ee5e51447e70a
https://doi.org/10.1016/j.sesci.2016.04.001
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....996ed1eb40f3006b120ee5e51447e70a
قاعدة البيانات: OpenAIRE