Ultrasonographic Assessment of Testicular Viability Using Heterogeneity Levels in Torsed Testicles

التفاصيل البيبلوغرافية
العنوان: Ultrasonographic Assessment of Testicular Viability Using Heterogeneity Levels in Torsed Testicles
المؤلفون: Ricardo Palmerola, Christopher Hartman, Zara Rahman, Michael Siev, Lane S. Palmer, Sleiman R. Ghorayeb, Patrick Samson
المصدر: The Journal of urology. 197(3 Pt 2)
سنة النشر: 2016
مصطلحات موضوعية: Acute scrotal pain, Pediatric emergency, Male, endocrine system, medicine.medical_specialty, Pathology, Adolescent, Urology, 030232 urology & nephrology, 03 medical and health sciences, 0302 clinical medicine, Temporal heterogeneity, Testis, Medicine, Testicular torsion, Humans, Spermatic Cord Torsion, Child, Retrospective Studies, Ultrasonography, Tissue Survival, 030219 obstetrics & reproductive medicine, Receiver operating characteristic, business.industry, Ultrasound, Infant, Newborn, Infant, medicine.disease, Child, Preschool, Radiology, business
الوصف: Gross testicular heterogeneity on ultrasound has been associated with testis loss following testicular torsion in children. We aimed to quantify the extent of temporal heterogeneity associated with testis loss in testicular torsion cases using a noninvasive technique to determine a HI (heterogeneity index) on ultrasound images.We retrospectively studied the records of patients who presented with acute scrotal pain to the Pediatric Emergency Department over a 6-year period. Ultrasound images of the affected testis and the unaffected contralateral testis were examined using a proprietary program to determine the extent of heterogeneity of each image. The difference between the HI of the torsed testis and that of the contralateral normal testis was termed ΔHI. Receiver operating characteristics curve analysis was performed to determine the ΔHI threshold for nonviability.Among 529 patients who presented with acute scrotal pain 147 had testicular torsion based on surgical findings. Of these 147 patients 110 (74.8%) were found to have a viable testis while 37 (25.2%) had a nonviable testis. Using the ΔHI cutoff of 0.394 or greater for nonviability, sensitivity and specificity were 100% and 94.5%, respectively. Positive and negative predictive values were 86% and 100%, respectively.Our results demonstrate that a quantifiable temporal gradation of heterogeneity exists and the heterogeneity index can be used as an objective parameter to determine the viability of a torsed testicle. By developing the technology to measure the heterogeneity index in real time, we could potentially identify which patients with testicular torsion have a nonviable testicle and, thus, would not require immediate surgical exploration.
تدمد: 1527-3792
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::9dac4641874e1d25a10107539f090d17
https://pubmed.ncbi.nlm.nih.gov/27992756
حقوق: CLOSED
رقم الأكسشن: edsair.doi.dedup.....9dac4641874e1d25a10107539f090d17
قاعدة البيانات: OpenAIRE