Simulating face-to-face tracheal intubation of a trapped patient: a randomized comparison of the LMA Fastrachtrade;, the GlideScopetrade;, and the Airtraqtrade; laryngoscope

التفاصيل البيبلوغرافية
العنوان: Simulating face-to-face tracheal intubation of a trapped patient: a randomized comparison of the LMA Fastrachtrade;, the GlideScopetrade;, and the Airtraqtrade; laryngoscope
المؤلفون: H. Hahouache, W. Abdi, X. Combes, J. Sudrial, Roland Amathieu, D. Luis, Gilles Dhonneur
المصدر: British journal of anaesthesia. 108(1)
سنة النشر: 2011
مصطلحات موضوعية: Adult, Male, medicine.medical_specialty, Supine position, medicine.medical_treatment, Laryngoscopy, Posture, Laryngoscopes, Airtraq, Manikins, Laryngeal Masks, Anesthesiology, medicine, Intubation, Intratracheal, Supine Position, Intubation, Humans, Prospective Studies, Airway Management, medicine.diagnostic_test, business.industry, Tracheal intubation, Equipment Design, respiratory system, Surgery, Anesthesiology and Pain Medicine, Treatment Outcome, Anesthesia, Data Interpretation, Statistical, Pharynx, Cervical collar, Female, Clinical Competence, Airway, business
الوصف: We undertook a prospective randomized comparison of the LMA Fastrach™, Airtraq™ laryngoscope, and GlideScope™ used for face-to-face tracheal intubation simulated to mimic an entrapped patient.Thirty senior emergency medicine physicians were trained in the use of the LMA Fastrach™, GlideScope™, and Airtraq™ laryngoscope with a standard airway trainer manikin (control). Participants were then asked to perform tracheal intubation in two difficult situations simulated on a difficult airway management manikin wearing a cervical collar. In Situation 1, the manikin was in the supine position with a difficult airway caused by stiffening the cervical spine. In Situation 2, the manikin was positioned to simulate face-to-face tracheal intubation. We measured intubation times, success rates for tracheal intubation, and the difficulty of tracheal intubation. Values are means (sd).In control and Situation 1, tracheal intubation details were similar. In Situation 2, face-to-face tracheal intubation success rate was increased with the Airtraq™ (100%), when compared with that of the GlideScope™ (70%, P0.05) and LMA Fastrach™ (83%, P0.05). Face-to-face tracheal intubation was less difficult (visual analogue scale: 0-100) with the Airtraq™ 11 (6) when compared with the GlideScope™ [33 (14) s, P0.01)] and LMA Fastrach™ [22 (21) s, P0.01]. The face-to-face tracheal intubation time was shorter with the Airtraq™ 14 (6) s than with the GlideScope™ [27 (18) s, P0.01] and Fastrach™ [28 (10) s, P0.01].The Airtraq™ laryngoscope was superior to both the GlideScope™ and LMA Fastrach™ during simulated face-to-face difficult tracheal intubation.
تدمد: 1471-6771
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::9f1384ddb18868da54c943abc11c3392
https://pubmed.ncbi.nlm.nih.gov/22037225
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....9f1384ddb18868da54c943abc11c3392