Prognostic Value of Thrombus Volume and Interaction With First-Line Endovascular Treatment Device Choice

التفاصيل البيبلوغرافية
العنوان: Prognostic Value of Thrombus Volume and Interaction With First-Line Endovascular Treatment Device Choice
المؤلفون: Henk van Voorst, Agnetha A.E. Bruggeman, Jurr Andriessen, Jan W. Hoving, Praneeta R. Konduri, Wenjin Yang, Manon Kappelhof, Nerea Arrarte Terreros, Yvo B.W.E.M. Roos, Wim H. van Zwam, Aad van der Lugt, Anouk van der Hoorn, Jelis Boiten, Stefan Roosendaal, Sjoerd Jenniskens, Matthan W.A. Caan, Henk A. Marquering, Bart J. Emmer, Charles B.L.M. Majoie, Diederik W.J. Dippel, Robert J. van Oostenbrugge, Jan Albert Vos, Ivo G.H. Jansen, Maxim J.H.L. Mulder, Robert- Jan B. Goldhoorn, Kars C.J. Compagne, Josje Brouwer, Sanne J. den Hartog, Wouter H. Hinsenveld, Bob Roozenbeek, Adriaan C.G.M. van Es, Jonathan M. Coutinho, Wouter J. Schonewille, Marieke J.H. Wermer, Marianne A.A. van Walderveen, Julie Staals, Jeannette Hofmeijer, Jasper M. Martens, Geert J. Lycklama à Nijeholt, Sebastiaan F. de Bruijn, Lukas C. van Dijk, H. Bart van der Worp, Rob H. Lo, Ewoud J. van Dijk, Hieronymus D. Boogaarts, J. de Vries, Paul L.M. de Kort, Julia van Tuijl, Jo P. Peluso, Puck Fransen, Jan S.P. van den Berg, Boudewijn A.A.M. van Hasselt, Leo A.M. Aerden, René J. Dallinga, Maarten Uyttenboogaart, Omid Eschgi, Reinoud P.H. Bokkers, Tobien H.C.M.L. Schreuder, Roel J.J. Heijboer, Koos Keizer, Lonneke S.F. Yo, Heleen M. den Hertog, Emiel J.C. Sturm, Paul J.A.M. Brouwers, Marieke E.S. Sprengers, René van den Berg, Albert J. Yoo, Ludo F.M. Beenen, Alida A. Postma, Bas F.W. van der Kallen, Ido R. van den Wijngaard, Joost Bot, Pieter-Jan van Doormaal, Anton Meijer, Elyas Ghariq, Marc P. van Proosdij, G. Menno Krietemeijer, Rob Lo, Dick Gerrits, Wouter Dinkelaar, Auke P.A. Appelman, Bas Hammer, Sjoert Pegge, Saman Vinke, H. Zwenneke Flach, Hester F. Lingsma, Naziha el Ghannouti, Martin Sterrenberg, Wilma Pellikaan, Rita Sprengers, Marjan Elfrink, Michelle Simons, Marjolein Vossers, Joke de Meris, Tamara Vermeulen, Annet Geerlings, Gina van Vemde, Tiny Simons, Gert Messchendorp, Nynke Nicolaij, Hester Bongenaar, Karin Bodde, Sandra Kleijn, Jasmijn Lodico, Hanneke Droste, Maureen Wollaert, Sabrina Verheesen, D. Jeurrissen, Erna Bos, Yvonne Drabbe, Michelle Sandiman, Nicoline Aaldering, Berber Zweedijk, Jocova Vervoort, Eva Ponjee, Sharon Romviel, Karin Kanselaar, Denn Barning, Esmee Venema, Vicky Chalos, Ralph R. Geuskens, Tim van Straaten, Saliha Ergezen, Roger R.M. Harmsma, Daan Muijres, Anouk de Jong, Olvert A. Berkhemer, Anna M.M. Boers, J. Huguet, P.F.C. Groot, Marieke A. Mens, Katinka R. van Kranendonk, Kilian M. Treurniet, Manon L. Tolhuisen, Heitor Alves, Annick J. Weterings, Eleonora L.F. Kirkels, Eva J.H.F. Voogd, Lieve M. Schupp, Sabine Collette, Adrien E.D. Groot, Natalie E. LeCouffe, Haryadi Prasetya, Lucas A. Ramos
المساهمون: Radiology and Nuclear Medicine, Biomedical Engineering and Physics, ANS - Brain Imaging, APH - Methodology, APH - Aging & Later Life, ACS - Atherosclerosis & ischemic syndromes, ANS - Neurovascular Disorders, ACS - Microcirculation, Pediatrics, Radiology and nuclear medicine, Damage and Repair in Cancer Development and Cancer Treatment (DARE), ​Basic and Translational Research and Imaging Methodology Development in Groningen (BRIDGE)
المصدر: Stroke, 54(4), 1056-1065. Lippincott Williams and Wilkins
MR CLEAN Registry Investigators 2023, ' Prognostic Value of Thrombus Volume and Interaction With First-Line Endovascular Treatment Device Choice ', Stroke, vol. 54, no. 4, pp. 1056-1065 . https://doi.org/10.1161/STROKEAHA.122.041606
Stroke, 54, 4, pp. 1056-1065
Stroke, 54, 1056-1065
Stroke, 54(4), 1056-1065. LIPPINCOTT WILLIAMS & WILKINS
سنة النشر: 2023
مصطلحات موضوعية: IMPACT, RECANALIZATION, GUIDELINES, functional status, All institutes and research themes of the Radboud University Medical Center, Brain Ischemia/diagnostic imaging, LENGTH, ischemic stroke, Humans, Ischemic Stroke/complications, thrombosis, Retrospective Studies, Advanced and Specialized Nursing, Other Research Radboud Institute for Health Sciences [Radboudumc 0], THROMBECTOMY, Endovascular Procedures/methods, Treatment Outcome, Thrombosis/diagnostic imaging, Thrombectomy/methods, stents, HEART, Neurology (clinical), prognosis, Cardiology and Cardiovascular Medicine, STROKE, Stroke/diagnostic imaging
الوصف: Background: A larger thrombus in patients with acute ischemic stroke might result in more complex endovascular treatment procedures, resulting in poorer patient outcomes. Current evidence on thrombus volume and length related to procedural and functional outcomes remains contradicting. This study aimed to assess the prognostic value of thrombus volume and thrombus length and whether this relationship differs between first-line stent retrievers and aspiration devices for endovascular treatment. Methods: In this multicenter retrospective cohort study, 670 of 3279 patients from the MR CLEAN Registry (Multicenter Randomized Clinical Trial of Endovascular Treatment for Acute Ischemic Stroke in the Netherlands) for endovascularly treated large vessel occlusions were included. Thrombus volume (0.1 mL) and length (0.1 mm) based on manual segmentations and measurements were related to reperfusion grade (expanded Treatment in Cerebral Infarction score) after endovascular treatment, the number of retrieval attempts, symptomatic intracranial hemorrhage, and a shift for functional outcome at 90 days measured with the reverted ordinal modified Rankin Scale (odds ratio >1 implies a favorable outcome). Univariable and multivariable linear and logistic regression were used to report common odds ratios (cORs)/adjusted cOR and regression coefficients (B/aB) with 95% CIs. Furthermore, a multiplicative interaction term was used to analyze the relationship between first-line device choice, stent retrievers versus aspiration device, thrombus volume, and outcomes. Results: Thrombus volume was associated with functional outcome (adjusted cOR, 0.83 [95% CI, 0.71–0.97]) and number of retrieval attempts (aB, 0.16 [95% CI, 0.16–0.28]) but not with the other outcome measures. Thrombus length was only associated with functional independence (adjusted cOR, 0.45 [95% CI, 0.24–0.85]). Patients with more voluminous thrombi had worse functional outcomes if endovascular treatment was based on first-line stent retrievers (interaction cOR, 0.67 [95% CI, 0.50–0.89]; P =0.005; adjusted cOR, 0.74 [95% CI, 0.55–1.0]; P =0.04). Conclusions: In this study, patients with a more voluminous thrombus required more endovascular thrombus retrieval attempts and had a worse functional outcome. Patients with a lengthier thrombus were less likely to achieve functional independence at 90 days. For more voluminous thrombi, first-line stent retrieval compared with first-line aspiration might be associated with worse functional outcome.
اللغة: English
تدمد: 0039-2499
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::a0921f9ff1419c75a2e24285d1f4cdc9
https://pure.amc.nl/en/publications/prognostic-value-of-thrombus-volume-and-interaction-with-firstline-endovascular-treatment-device-choice(f499dd53-851d-4260-adb0-af309bca6262).html
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....a0921f9ff1419c75a2e24285d1f4cdc9