Assessment of a Non-Invasive Brain Pulse Monitor to Measure Intra-Cranial Pressure Following Acute Brain Injury

التفاصيل البيبلوغرافية
العنوان: Assessment of a Non-Invasive Brain Pulse Monitor to Measure Intra-Cranial Pressure Following Acute Brain Injury
المؤلفون: Barry Dixon, Jessica M Sharkey, Elliot J Teo, Sally A Grace, Jacqui S Savage, Andrew Udy, Paul Smith, Jack Hellerstedt, John D Santamaria
المصدر: Medical Devices: Evidence and Research. 16:15-26
بيانات النشر: Informa UK Limited, 2023.
سنة النشر: 2023
مصطلحات موضوعية: Evidence and Research [Medical Devices], Biomedical Engineering, Medicine (miscellaneous)
الوصف: Barry Dixon,1– 3 Jessica M Sharkey,1 Elliot J Teo,1,2 Sally A Grace,1 Jacqui S Savage,1 Andrew Udy,4 Paul Smith,5,6 Jack Hellerstedt,1 John D Santamaria2 1Cyban Pty Ltd, Melbourne, VIC, Australia; 2Department of Critical Care Medicine, St Vincent’s Hospital, Melbourne, Australia; 3Department of Medicine, University of Melbourne, Melbourne, Vic, Australia; 4Department of Critical Care Medicine, The Alfred Hospital, Melbourne, Australia; 5Department of Neurosurgery, St Vincent’s Hospital, Melbourne, Australia; 6University of Melbourne Medical School, Melbourne, Vic, AustraliaCorrespondence: Barry Dixon, Department of Critical Care Medicine, St Vincent’s Hospital (Melbourne), 41 Victoria Parade, Fitzroy, VIC, 3065, Australia, Tel +61 3 9231 4425, Email barry.dixon@svha.org.auBackground: Intracranial pressure (ICP) monitoring requires placing a hole in the skull through which an invasive pressure monitor is inserted into the brain. This approach has risks for the patient and is expensive. We have developed a non-invasive brain pulse monitor that uses red light to detect a photoplethysmographic (PPG) signal arising from the blood vessels on the brain’s cortical surface. The brain PPG and the invasive ICP waveform share morphological features which may allow measurement of the intracranial pressure.Methods: We enrolled critically ill patients with an acute brain injury with invasive ICP monitoring to assess the new monitor. A total of 24 simultaneous invasive ICP and brain pulse monitor PPG measurements were undertaken in 12 patients over a range of ICP levels.Results: The waveform morphologies were similar for the invasive ICP and brain pulse monitor PPG approach. Both methods demonstrated a progressive increase in the amplitude of P2 relative to P1 with increasing ICP levels. An automated algorithm was developed to assess the PPG morphological features in relation to the ICP level. A correlation was demonstrated between the brain pulse waveform morphology and ICP levels, R2=0.66, P < 0.001.Conclusion: The brain pulse monitor’s PPG waveform demonstrated morphological features were similar to the invasive ICP waveform over a range of ICP levels, these features may provide a method to measure ICP levels.Trial Registration: ACTRN12620000828921.Keywords: intracranial pressure, acute brain injury, monitoring, non-invasive, photoplethysmography
وصف الملف: text/html
تدمد: 1179-1470
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::a4142d5f3f831b9a6d5d81276b9f9b94
https://doi.org/10.2147/mder.s398193
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....a4142d5f3f831b9a6d5d81276b9f9b94
قاعدة البيانات: OpenAIRE