Internal calibration for opportunistic computed tomography muscle density analysis

التفاصيل البيبلوغرافية
العنوان: Internal calibration for opportunistic computed tomography muscle density analysis
المؤلفون: Ainsley C. J. Smith, Justin J. Tse, Tadiwa H. Waungana, Kirsten N. Bott, Michael T. Kuczynski, Andrew S. Michalski, Steven K. Boyd, Sarah L. Manske
بيانات النشر: Cold Spring Harbor Laboratory, 2022.
سنة النشر: 2022
مصطلحات موضوعية: Multidisciplinary, Bone Density, Phantoms, Imaging, Muscles, Calibration, Quality of Life, Animals, Cattle, Tomography, X-Ray Computed
الوصف: Introduction Muscle weakness can lead to reduced physical function and quality of life. Computed tomography (CT) can be used to assess muscle health through measures of muscle cross-sectional area and density loss associated with fat infiltration. However, there are limited opportunities to measure muscle density in clinically acquired CT scans because a density calibration phantom, allowing for the conversion of CT Hounsfield units into density, is typically not included within the field-of-view. For bone density analysis, internal density calibration methods use regions of interest within the scan field-of-view to derive the relationship between Hounsfield units and bone density, but these methods have yet to be adapted for muscle density analysis. The objective of this study was to design and validate a CT internal calibration method for muscle density analysis. Methodology We CT scanned 10 bovine muscle samples using two scan protocols and five scan positions within the scanner bore. The scans were calibrated using internal calibration and a reference phantom. We tested combinations of internal calibration regions of interest (e.g., air, blood, bone, muscle, adipose). Results We found that the internal calibration method using two regions of interest, air and adipose or blood, yielded accurate muscle density values (< 1% error) when compared with the reference phantom. The muscle density values derived from the internal and reference phantom calibration methods were highly correlated (R2 > 0.99). The coefficient of variation for muscle density across two scan protocols and five scan positions was significantly lower for internal calibration (mean = 0.33%) than for Hounsfield units (mean = 6.52%). There was no difference between coefficient of variation for the internal calibration and reference phantom methods. Conclusions We have developed an internal calibration method to produce accurate and reliable muscle density measures from opportunistic computed tomography images without the need for calibration phantoms.
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::a66703f5039bfbc894dbcc2bff812549
https://doi.org/10.1101/2022.08.05.502969
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....a66703f5039bfbc894dbcc2bff812549
قاعدة البيانات: OpenAIRE