Diagnostic accuracy of sub-mSv prospective ECG-triggering cardiac CT in young infant with complex congenital heart disease

التفاصيل البيبلوغرافية
العنوان: Diagnostic accuracy of sub-mSv prospective ECG-triggering cardiac CT in young infant with complex congenital heart disease
المؤلفون: Rong Zhen Ouyang, Ai Min Sun, Yu Min Zhong, Jian Ying Li, Qian Wang, Han Sheng Qiu, Shi Yu Wang, Wei Gao, Li Wei Hu
المصدر: The International Journal of Cardiovascular Imaging. 32:991-998
بيانات النشر: Springer Science and Business Media LLC, 2016.
سنة النشر: 2016
مصطلحات موضوعية: Heart Defects, Congenital, Male, medicine.medical_specialty, Tomography Scanners, X-Ray Computed, Computed Tomography Angiography, Cardiac-Gated Imaging Techniques, Coronary Angiography, Radiation Dosage, 030218 nuclear medicine & medical imaging, Electrocardiography, 03 medical and health sciences, 0302 clinical medicine, Left coronary artery, Predictive Value of Tests, medicine.artery, Positive predicative value, Multidetector Computed Tomography, Humans, Medicine, Radiology, Nuclear Medicine and imaging, Prospective Studies, Prospective cohort study, Cardiac imaging, Observer Variation, medicine.diagnostic_test, business.industry, Age Factors, Infant, Newborn, Infant, Reproducibility of Results, Radiation Exposure, Coronary Vessels, Coronary arteries, medicine.anatomical_structure, 030220 oncology & carcinogenesis, Right coronary artery, Predictive value of tests, Radiographic Image Interpretation, Computer-Assisted, Female, Radiology, Cardiology and Cardiovascular Medicine, business
الوصف: To explore the clinical value and evaluate the diagnostic accuracy of sub-mSv low-dose prospective ECG-triggering cardiac CT (CCT) in young infants with complex congenital heart disease (CHD). A total of 102 consecutive infant patients (53 boys and 49 girls with mean age of 2.9 ± 2.4 m and weight less than 5 kg) with complex CHD were prospectively enrolled. Scans were performed on a 64-slice high definition CT scanner with low dose prospective ECG-triggering mode and reconstructed with 80 % adaptive statistical iterative reconstruction algorithm. All studies were performed during free breathing with sedation. The subjective image quality was evaluated by 5-point grading scale and interobserver variability was calculated. The objective image noise (standard deviation, SD) and contrast to noise ratio (CNR) was calculated. The effective radiation dose from the prospective ECG-triggering mode was recorded and compared with the virtual conventional retrospective ECG-gating mode. The detection rate for the origin of coronary artery was calculated. All patients also underwent echocardiography before CCT examination. 81 patients had surgery and their preoperative CCT and echocardiography findings were compared with the surgical results and sensitivity, specificity, positive and negative predictive values and accuracy were calculated for separate cardiovascular anomalies. Heart rates were 70–161 beats per minute (bpm) with mean value of 129.19 ± 14.52 bpm. The effective dose of 0.53 ± 0.15 mSv in the prospective ECG-triggering cardiac CT was lower than the calculated value in a conventional retrospective ECG-gating mode (2.00 ± 0.35 mSv) (p
تدمد: 1573-0743
1569-5794
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::a91eafb9bf0ab811b92c2d515afda37c
https://doi.org/10.1007/s10554-016-0854-8
حقوق: CLOSED
رقم الأكسشن: edsair.doi.dedup.....a91eafb9bf0ab811b92c2d515afda37c
قاعدة البيانات: OpenAIRE