Use of on-line mass spectrometric detection in capillary electrochromatography

التفاصيل البيبلوغرافية
العنوان: Use of on-line mass spectrometric detection in capillary electrochromatography
المؤلفون: Gargi Choudhary, Alex Apffel, William S. Hancock, Hongfeng Yin
المصدر: Journal of Chromatography A. 887:85-101
بيانات النشر: Elsevier BV, 2000.
سنة النشر: 2000
مصطلحات موضوعية: Capillary electrochromatography, Electrospray, Chromatography, Capillary action, Chemistry, Electrospray ionization, Organic Chemistry, Analytical chemistry, Electrophoresis, Capillary, General Medicine, Mass spectrometry, Biochemistry, Capillary electrophoresis–mass spectrometry, Mass Spectrometry, Analytical Chemistry, Capillary electrophoresis, Electrochromatography, Terminology as Topic, cardiovascular system
الوصف: Capillary electrochromatography (CEC) is a liquid phase analytical separation technique that is generally carried out with packed capillary columns by electroosmotically driven mobile phase at high electric field strength. The analytes are separated by virtue of the differences in their distribution between the mobile and stationary phases and, if charged in their electrophoretic mobilities as well. It is thus considered a hybrid of liquid chromatography and capillary electrophoresis and is expected to combine the high peak efficiency of capillary zone electrophoresis (CZE) with the versatility and loading capacity of HPLC. This review explores the potential use of on-line mass spectrometric detection for CEC. It discusses key design issues that focus on the physical and electrical arrangement of the CEC column with respect to the electrospray orifice inlet. The salient features of the sheathless, sheath flow and liquid junction interfaces that are frequently employed while coupling a CEC column to an electrospray ionization mass spectrometry system are also highlighted. Possible configurations of the CEC column outlet that would obviate the need for pressurizing the capillary column are also presented. While coupling CEC with MS both the nature of the interface and the configuration of the column outlet will determine the optimal arrangement. The review also discusses bandspreading that occurs when a connecting tube is employed to transfer mobile phase from the column outlet to the atmospheric region of the electrospray source with a concomitant loss in sensitivity. Selected examples that highlight the potential of this technique for a wide range of applications are also presented.
تدمد: 0021-9673
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::b3ab5900f5c16fc336f9948d4eec68a3
https://doi.org/10.1016/s0021-9673(00)00530-6
حقوق: CLOSED
رقم الأكسشن: edsair.doi.dedup.....b3ab5900f5c16fc336f9948d4eec68a3
قاعدة البيانات: OpenAIRE