العنوان: Influence of Cycloversions Induced by Head Tilt on Scanning Laser Polarimetry Parameters
المؤلفون: Andrea B. Jehn, René M. Müri, Daniel S. Mojon
المصدر: Ophthalmologica. 217:311-314
بيانات النشر: S. Karger AG, 2003.
سنة النشر: 2003
مصطلحات موضوعية: Adult, Torsion Abnormality, Materials science, Eye Movements, Rotation, genetic structures, Fundus Oculi, Head tilt, Scanning laser polarimetry, Fundus (eye), law.invention, Ocular Motility Disorders, Optics, law, Optic Nerve Diseases, Humans, In patient, Birefringence, business.industry, Lasers, Eye movement, General Medicine, Middle Aged, Laser, Sensory Systems, Ophthalmology, Head Movements, Visual Field Tests, Head (vessel), business, Nuclear medicine
الوصف: Objective: To study the influence of cycloversions induced by head tilt on parameters of scanning laser polarimetry. Methods: Five left and five right eyes of 9 normal subjects were measured in seven different head tilt positions by one examiner using a scanning laser polarimeter (Nerve Fiber Analyzer, NFA II, LDT Inc., San Diego, Calif., USA). Images were acquired for the following head tilt positions: upright, 10, 20, 30° to the right, and 10, 20, 30° to the left. For each position five to eight images of the peripapillary area were recorded. Objective cycloversions were determined trigonometrically on the fundus pictures provided by the scanning laser ophthalmoscope. Parameters acquired for different head positions were compared using a Friedmann’s two-way analysis of variance. Results: Average objective cyclodeviations were 5.9° for the 10° head tilts, 11.2° for the 20° head tilts, and 18.9° for the 30° head tilts. Head tilts to the right in left eyes and to the left in right eyes (both of them corresponding to an incycloposition) induced a significant increase in several parameters (p < 0.05). Head tilts to the left in left eyes and to the right in right eyes (both corresponding to an excycloposition) showed no influence on parameters (p > 0.05). Conclusions: Ocular incycloposition has a significant influence on several scanning laser polarimetry parameters. Therefore, evaluation is limited in patients having an incyclorotation of the nonfixating eye with the head in an upright position or in patients having a head tilt inducing an incyclorotation.
تدمد: 1423-0267
0030-3755
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::b716c323c76a11c095eabcb70240623b
https://doi.org/10.1159/000071343
حقوق: CLOSED
رقم الأكسشن: edsair.doi.dedup.....b716c323c76a11c095eabcb70240623b
قاعدة البيانات: OpenAIRE