Positioning error and expanding margins of planning target volume with kilovoltage cone beam computed tomography for prostate cancer radiotherapy

التفاصيل البيبلوغرافية
العنوان: Positioning error and expanding margins of planning target volume with kilovoltage cone beam computed tomography for prostate cancer radiotherapy
المؤلفون: Yi-Qun Liu, Gang Wang, Yinxiang Hu, Hongmin Dong, Wenling Wang
المصدر: OncoTargets and therapy
بيانات النشر: Informa UK Limited, 2018.
سنة النشر: 2018
مصطلحات موضوعية: Kilovoltage Cone Beam Computed Tomography, Supine position, medicine.medical_treatment, Planning target volume, positioning error, OncoTargets and Therapy, 030218 nuclear medicine & medical imaging, 03 medical and health sciences, Prostate cancer, 0302 clinical medicine, medicine, Pharmacology (medical), Original Research, Image-guided radiation therapy, business.industry, Significant difference, image-guided radiotherapy, Radical radiotherapy, prostate cancer, medicine.disease, Radiation therapy, kilovoltage cone beam CT, planning target volume, Oncology, 030220 oncology & carcinogenesis, business, Nuclear medicine
الوصف: Gang Wang, Wen-Ling Wang, Yi-Qun Liu, Hong-Min Dong, Yin-Xiang Hu Department of Abdominal Oncology, Affiliated Hospital of Guizhou Medical University, Guizhou Cancer Hospital, Guiyang, People’s Republic of China Objective: In this study, prostate cancer patients were treated with image-guided radiotherapy (IGRT). The translational positioning errors were discussed to provide the basis for determining margins of the planning target volume (PTV). Methods: Thirty prostate cancer patients were treated with radical radiotherapy using the IGRT system. Patients were placed in the supine position and underwent kilovoltage cone beam computed tomography (KVCBCT) scans before radiotherapy. A total of 447 images were acquired. The translational positioning errors were obtained in three linear directions which were X (left-to-right), Y (superior-to-inferior) and Z (anterior-to-posterior) axes (denoted as Lx, Ly and Lz) through the contrast between images adjusted with gray and manual registrations and the planning CT images. Rotational errors were denoted as Rx, Ry and Rz. Results: Uncorrected translational errors Lx, Ly and Lz in the 251 positioning images were all higher than those after correction, and the differences were all statistically significant (P=0.000, 0.037 and 0.004, respectively). For rotational errors Rx, Ry and Rz, only Rx had a significant difference before and after correction (P=0.044). Before correction, PTV margins in the X, Y and Z directions were 0.61, 0.78 and 0.41cm, respectively; after correction, these were 0.17, 0.12 and 0.17cm, respectively. Conclusion: KVCBCT can be applied to measure positioning errors in prostate cancer radiotherapy and correct these errors in real time through the 6° robotic patient positioning system, in order to improve patient positioning accuracy. The application of IGRT with KVCBCT may reduce PTV margins. Keywords: prostate cancer, image-guided radiotherapy, kilovoltage cone beam CT, positioning error, planning target volume
وصف الملف: text/html
تدمد: 1178-6930
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::c047668144d34501fdbfa5fb0caae160
https://doi.org/10.2147/ott.s152915
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....c047668144d34501fdbfa5fb0caae160
قاعدة البيانات: OpenAIRE