Validation of the APTIMA Combo 2 assay for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae in SurePath liquid-based pap test samples taken with different collection devices

التفاصيل البيبلوغرافية
العنوان: Validation of the APTIMA Combo 2 assay for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae in SurePath liquid-based pap test samples taken with different collection devices
المؤلفون: Craig Hill, Diane MacEachern, J. Kapala, Ruth Ewert, Marek Smieja, Max Chernesky, Dan Jang, Christine Doucette, Anne MacDonald, Cindy Pritchard, Eder Portillo, J. Sumner
المصدر: Sexually transmitted diseases. 36(9)
سنة النشر: 2009
مصطلحات موضوعية: Microbiology (medical), Sexually transmitted disease, medicine.medical_specialty, Serial dilution, Chlamydia trachomatis, Dermatology, Cervix Uteri, medicine.disease_cause, Sensitivity and Specificity, Specimen Handling, Gonorrhea, Predictive Value of Tests, medicine, Humans, Chlamydiaceae, Gynecology, Vaginal Smears, Bacteriological Techniques, biology, business.industry, Public Health, Environmental and Occupational Health, Chlamydia Infections, biology.organism_classification, Neisseria gonorrhoeae, Culture Media, Infectious Diseases, Infected patient, Chlamydiales, Female, Reagent Kits, Diagnostic, business, Nucleic Acid Amplification Techniques, Liquid-based Pap Test
الوصف: Mocked samples of Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (GC) diluted in SurePath liquid-based Pap (L-Pap) fluid were detected by the APTIMA Combo 2 assay to end points 10-fold greater than dilutions in specimen transport media. Pooled L-Pap clinical specimens yielded CT-positive results after storage at room temperature for 10 days. Based on an infected patient standard for comparison, cervical swabs, urine, and SurePath L-Pap test samples collected with a SurePath cervical broom or ThinPrep cytobrush from 520 women then tested by APTIMA Combo 2 assay, detected 25 (4.8%) with CT, 5 (1.0%) with (GC), and 3 (0.6%) with both. Percent sensitivities (80-84), specificities (99.8-100), positive (99.5-100) and negative (99.2-99) predictive values of SurePath L-Pap for CT were validated as similar to those reported in a previously published multicenter trial. All values for GC were 100%. One collection device was not significantly better than the other.
تدمد: 1537-4521
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::c0e239298e88195535a6e5696befeb66
https://pubmed.ncbi.nlm.nih.gov/19661842
رقم الأكسشن: edsair.doi.dedup.....c0e239298e88195535a6e5696befeb66
قاعدة البيانات: OpenAIRE