Robotic thoracoscopic plication for symptomatic diaphragm paralysis

التفاصيل البيبلوغرافية
العنوان: Robotic thoracoscopic plication for symptomatic diaphragm paralysis
المؤلفون: Iosif Gulkarov, Homayon Pournik, Taehee Kwak, Richard S. Lazzaro, Daniel G. Ciaburri, Anthony J. Tortolani
المصدر: Journal of robotic surgery. 6(4)
سنة النشر: 2011
مصطلحات موضوعية: medicine.medical_specialty, Diaphragm paralysis, business.industry, Open thoracotomy, Health Informatics, ELEVATED HEMIDIAPHRAGM, musculoskeletal system, Diaphragmatic paralysis, Significant elevation, Diaphragm (structural system), Surgery, Pulmonary function testing, Anesthesia, Medicine, Robotic surgery, business
الوصف: Diaphragmatic paralysis is an uncommon condition characterized by significant elevation of a hemidiaphragm, and can cause dyspnea. The goal of diaphragm plication is to improve dyspnea by correcting the dysfunctional movement of a diaphragm during inspiration. Minimally invasive thoracoscopic diaphragm plication has been widely used and has been reported to lead to significant improvements in dyspnea and postoperative pulmonary function. Advantages of thoracoscopic plication compared to open thoracotomy are less postoperative pain and shorter hospitalization, yet technical difficulties due to limited workspace afforded by the ribcage and the elevated hemidiaphragm have been a major drawback in using the thoracoscopic approach for this disorder. We describe our experience with robotic thoracoscopic plication for the treatment of diaphragmatic paralysis. This is, to our knowledge, the first report of this kind.
تدمد: 1863-2483
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::c24f818e98ec253b5d77b715d3185ebf
https://pubmed.ncbi.nlm.nih.gov/27628476