In vitro study on the accuracy of sleeveless guided endodontics and treatment of a complex upper lateral incisor

التفاصيل البيبلوغرافية
العنوان: In vitro study on the accuracy of sleeveless guided endodontics and treatment of a complex upper lateral incisor
المؤلفون: A. Torres, M. Dierickx, W. Coucke, MS. Pedano, P. Lambrechts, R. Jacobs
المصدر: Journal of Dentistry. 131:104466
بيانات النشر: Elsevier BV, 2023.
سنة النشر: 2023
مصطلحات موضوعية: 3-Dimensional printing, Cone Beam Computed Tomography, Dental Pulp Calcification, Guided Endodontics, General Dentistry, Accuracy
الوصف: PURPOSE: The present study aims to assess the accuracy of sleeveless guided endodontics for root canal treatment of severe pulp canal obliteration (PCO) in 3D printed jaws. Additionally, the treatment of a complex lateral incisor is presented to illustrate the use of sleeveless guides in a clinical situation. METHODS: Two cone-beam computed tomography (CBCT) volumes of an upper and lower jaw were selected to design 3D printed models with PCO. Virtual planning of the access cavities was performed from right to left second premolar. Then, the models were mounted into a phantom head to simulate an actual patient. Two operators with different levels of experience in endodontics performed guided access cavities. The handpiece was guided by guiding rails placed against each other on the sides of the tooth. A post-operative CBCT scan was taken for analysis. RESULTS: Eighty-eight guided access cavities (44 per operator) were drilled on eight 3D printed models. The mean length of the access cavities was 15.3 mm, with a mean coronal and apical deviation of 0.5 mm and 0.7 mm respectively. The mean angular deviation was 1.5°. No statistically significant difference was found between operators for the three measured parameters. CONCLUSIONS: This study demonstrates, within its limitations, that sleveless guides represent an accurate method for guided endodontic treatment. No statistically significant difference between operators was found when using the guide. CLINICAL SIGNIFICANCE: This method offers a valuable alternative to conventional endodontic guides with similar accuracy results. ispartof: JOURNAL OF DENTISTRY vol:131 ispartof: location:England status: published
وصف الملف: Print-Electronic
تدمد: 0300-5712
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::c7eda607993828c576fd5ac636aaf4e6
https://doi.org/10.1016/j.jdent.2023.104466
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....c7eda607993828c576fd5ac636aaf4e6
قاعدة البيانات: OpenAIRE