Reduced‐field of view three‐dimensional MR acoustic radiation force imaging with a low‐rank reconstruction for targeting transcranial focused ultrasound

التفاصيل البيبلوغرافية
العنوان: Reduced‐field of view three‐dimensional MR acoustic radiation force imaging with a low‐rank reconstruction for targeting transcranial focused ultrasound
المؤلفون: Huiwen Luo, Michelle K. Sigona, Thomas J. Manuel, Marshal A. Phipps, Li M. Chen, Charles F. Caskey, William A. Grissom
المصدر: Magnetic Resonance in Medicine. 88:2419-2431
بيانات النشر: Wiley, 2022.
سنة النشر: 2022
مصطلحات موضوعية: Imaging, Three-Dimensional, Phantoms, Imaging, Sepharose, Graphite, Radiology, Nuclear Medicine and imaging, Acoustics, Prospective Studies, Magnetic Resonance Imaging
الوصف: To rapidly image and localize the focus in MR-guided focused ultrasound (FUS) while maintaining a low ultrasound duty cycle to minimize tissue effects.MR-acoustic radiation force imaging (ARFI) is key to targeting FUS procedures such as neuromodulation, and works by encoding ultrasound-induced displacements into the phase of MR images. However, it can require long scan times to cover a volume of tissue, especially when minimizing the FUS dose during targeting is paramount. To simultaneously minimize scan time and the FUS duty cycle, a 2-min three-dimensional (3D) reduced-FOV spin echo ARFI scan with two-dimensional undersampling was implemented at 3T with a FUS duty cycle of 0.85%. The 3D k-space sampling scheme incorporated uniform undersampling in one phase-encoded axis and partial Fourier (PF) sampling in the other. The scan interleaved FUS-on and FUS-off data collection to improve displacement map quality via a joint low-rank image reconstruction. Experiments in agarose and graphite phantoms and living macaque brains for neuromodulation and blood-brain barrier opening studied the effects of the sampling and reconstruction strategy on the acquisition, and evaluated its repeatability and accuracy.In the phantom, the distances between displacement centroids of 10 prospective reconstructions and a fully sampled reference were below 1 mm. In in vivo brain, the distances between centroids ranged from 1.3 to 2.1 mm. Results in phantom and in vivo brain both showed that the proposed method can recover the FUS focus compared to slower fully sampled scans.The proposed 3D MR-ARFI reduced-FOV method enables rapid imaging of the FUS focus while maintaining a low FUS duty cycle.
تدمد: 1522-2594
0740-3194
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::ca9029755c03b01f430f3e3682ffee59
https://doi.org/10.1002/mrm.29403
حقوق: CLOSED
رقم الأكسشن: edsair.doi.dedup.....ca9029755c03b01f430f3e3682ffee59
قاعدة البيانات: OpenAIRE