Numerical Implementation of Representative Mobile Phone Models for Epidemiological Studies

التفاصيل البيبلوغرافية
العنوان: Numerical Implementation of Representative Mobile Phone Models for Epidemiological Studies
المؤلفون: Sooyung Lee, Byungje Lee, Elisabeth Cardis, Seon-Eui Hong, Yonghyun Yoon, Ae-Kyoung Lee, Hyung-Do Choi
المصدر: Dipòsit Digital de la UB
Universidad de Barcelona
Recercat. Dipósit de la Recerca de Catalunya
instname
بيانات النشر: Korean Institute of Electromagnetic Engineering and Science, 2016.
سنة النشر: 2016
مصطلحات موضوعية: Engineering, Electromagnetic absorption, Human head, Frequency band, business.industry, Brain, Specific absorption rate, 020206 networking & telecommunications, 02 engineering and technology, Electromagnetisme, Imaging phantom, 030218 nuclear medicine & medical imaging, 03 medical and health sciences, Electromagnetism, 0302 clinical medicine, Phone, Mobile phone, 0202 electrical engineering, electronic engineering, information engineering, Antenna (radio), Cervell, business, Simulation
الوصف: This paper describes an implementation method and the results of numerical mobile phone models representing real phone models that have been released on the Korean market since 2002. The aim is to estimate the electromagnetic absorption in the human brain for casecontrol studies to investigate health risks related to mobile phone use. Specific absorption rate (SAR) compliance test reports about commercial phone models were collected and classified in terms of elements such as the external body shape, the antenna, and the frequency band. The design criteria of a numerical phone model representing each type of phone group are as follows. The outer dimensions of the phone body are equal to the average dimensions of all commercial models with the same shape. The distance and direction of the maximum SAR from the earpiece and the area above –3 dB of the maximum SAR are fitted to achieve the average obtained by measuring the SAR distributions of the corresponding commercial models in a flat phantom. Spatial peak 1-g SAR values in the cheek and tilt positions against the specific anthropomorphic mannequin phantom agree with average data on all of the same type of commercial models. Second criterion was applied to only a few types of models because not many commercial models were available. The results show that, with the exception of one model, the implemented numerical phone models meet criteria within 30%.
وصف الملف: application/pdf
تدمد: 2234-8409
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::cbac10f2f3ec88c58fb964396ba6555b
https://doi.org/10.5515/jkiees.2016.16.2.87
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....cbac10f2f3ec88c58fb964396ba6555b
قاعدة البيانات: OpenAIRE