Is it better to use two elastographic methods for liver fibrosis assessment?

التفاصيل البيبلوغرافية
العنوان: Is it better to use two elastographic methods for liver fibrosis assessment?
المؤلفون: Radu Badea, Mircea Focsa, Monica Lupsor, Simona Bota, Roxana Sirli, Mirela Danila, Ioan Sporea, Alina Popescu
بيانات النشر: Baishideng Publishing Group Co., Limited, 2011.
سنة النشر: 2011
مصطلحات موضوعية: Adult, Liver Cirrhosis, Male, Pathology, medicine.medical_specialty, Brief Article, Liver fibrosis, Elasticity Imaging Techniques, Liver stiffness, Predictive Value of Tests, medicine, Humans, Combined method, medicine.diagnostic_test, business.industry, fungi, Gastroenterology, food and beverages, Reproducibility of Results, General Medicine, Hepatitis C, Chronic, Middle Aged, Liver biopsy, Predictive value of tests, Female, Transient elastography, business, Significant fibrosis
الوصف: To find out if by combining 2 ultrasound based elastographic methods: acoustic radiation force impulse (ARFI) elastography and transient elastography (TE), we can improve the prediction of fibrosis in patients with chronic hepatitis C.Our study included 197 patients with chronic hepatitis C. In each patient, we performed, in the same session, liver stiffness (LS) measurements by means of TE and ARFI, respectively, and liver biopsy (LB), assessed according to the Metavir score. 10 LS measurements were performed both by TE and ARFI; median values were calculated and expressed in kilopascals (kPa) and meters/second (m/s), respectively. Only TE and ARFI measurements with IQR30% and SR ≥ 60% were considered reliable.On LB 13 (6.6%) patients had F0, 32 (16.2%) had F1, 52 (26.4%) had F2, 47 (23.9%) had F3, and 53 (26.9%) had F4. A direct, strong correlation was found between TE measurements and fibrosis (r = 0.741), between ARFI and fibrosis (r = 0.730) and also between TE and ARFI (r = 0.675). For predicting significant fibrosis (F ≥ 2), for a cut-off of 6.7 kPa, TE had 77.5% sensitivity (Se) and 86.5% specificity (Sp) [area under the receiver operating characteristic curve (AUROC) 0.87] and for a cut-off of 1.2 m/s, ARFI had 76.9% Se and 86.7% Sp (AUROC 0.84). For predicting cirrhosis (F = 4), for a cut-off of 12.2 kPa, TE had 96.2% Se and 89.6% Sp (AUROC 0.97) and for a cut-off of 1.8 m/s, ARFI had 90.4% Se and 85.6% Sp (AUROC 0.91). When both elastographic methods were taken into consideration, for predicting significant fibrosis (F ≥ 2), (TE ≥ 6.7 kPa and ARFI ≥ 1.2 m/s) we obtained 60.5% Se, 93.3% Sp, 96.8% positive predictive value (PPV), 41.4% negative predictive value (NPV) and 68% accuracy, while for predicting cirrhosis (TE ≥ 12.2 kPa and ARFI ≥ 1.8 m/s) we obtained 84.9% Se, 94.4% Sp, 84.9% PPV, 94.4% NPV and 91.8% accuracy.TE used in combination with ARFI is highly specific for predicting significant fibrosis; therefore when the two methods are concordant, liver biopsy can be avoided.
اللغة: English
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::d28df78d35b7d0ca62e9e359e1414342
https://europepmc.org/articles/PMC3181444/
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....d28df78d35b7d0ca62e9e359e1414342
قاعدة البيانات: OpenAIRE