A Cluster-based Model Using Functional Methods Requires Less Operator Experience for Reliable Gait Analysis: A Preliminary Study of Intra- and Inter-assessor Reliability

التفاصيل البيبلوغرافية
العنوان: A Cluster-based Model Using Functional Methods Requires Less Operator Experience for Reliable Gait Analysis: A Preliminary Study of Intra- and Inter-assessor Reliability
المؤلفون: Lindsay Millar, Arjan Buis, Lin Meng, Craig Child
المصدر: EMBC
سنة النشر: 2020
مصطلحات موضوعية: 030222 orthopedics, Motion analysis, medicine.medical_specialty, Computer science, 0206 medical engineering, Reproducibility of Results, 02 engineering and technology, Kinematics, Manipulation, Osteopathic, 020601 biomedical engineering, Gait, 03 medical and health sciences, 0302 clinical medicine, Gait (human), Physical medicine and rehabilitation, Gait analysis, medicine, Animals, Humans, Manipulation, Orthopedic, Range of Motion, Articular, Reliability (statistics)
الوصف: Reliability of three-dimensional gait analysis is important for repetitive assessments in clinical or research studies. In this paper, we hypothesized that a Strathclyde Functional Cluster Model (SFCM) in which all the joint centers and flexion axes were determined by functional methods, could improve the reliability of joint kinematics within and between operators’ sessions compared to an anatomical model, Plug-in Gait (PiG). A preliminary study of intra- and inter-assessor reliability of the SFCM was been analyzed and compared to the PiG. One able-bodied participant performed eight sessions measured by four operators who have different experience level on the two models. Intra- and inter-operator reliability of the SFCM and PiG were assessed using the intraclass correlation coefficient (ICC) and standard deviation (SD). Results showed that the SFCM generated smaller SD and greater ICC values for all joint variables compared to the PiG in the inter-operator condition, suggesting that functional methods could improve the inter-operator reliability. Moreover, the intra-operator ICC results indicated that the SFCM performance was less influenced by operator experience compared to the PiG. In conclusion, as the model requires less palpation of ALs, it would benefit the users who have less experience in practical use.
تدمد: 2694-0604
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::df53cf847ea2efd5b166e3d6de1f0c68
https://pubmed.ncbi.nlm.nih.gov/33018674
حقوق: CLOSED
رقم الأكسشن: edsair.doi.dedup.....df53cf847ea2efd5b166e3d6de1f0c68
قاعدة البيانات: OpenAIRE