Novel temperature-controlled sleep system to improve sleep: a proof-of-concept study

التفاصيل البيبلوغرافية
العنوان: Novel temperature-controlled sleep system to improve sleep: a proof-of-concept study
المؤلفون: Shahab Haghayegh, Sepideh Khoshnevis, Michael H. Smolensky, Ramon C. Hermida, Richard J. Castriotta, Eva Schernhammer, Kenneth R. Diller
المصدر: Journal of sleep researchREFERENCES. 31(6)
سنة النشر: 2022
مصطلحات موضوعية: Male, Behavioral Neuroscience, Cognitive Neuroscience, Temperature, Humans, General Medicine, Skin Temperature, Sleep, Proof of Concept Study, Body Temperature, Body Temperature Regulation, Circadian Rhythm
الوصف: The sleep-wake cycle is regulated by circadian Process C and homeostatic Process S. Selective thermal stimulation (STS) of the cervical spine region enhances glabrous skin blood flow (GSBF) and augments body heat dissipation to increase distal-to-proximal skin gradient (DPG) causing decrease of core body temperature (CBT), which can shorten sleep onset latency (SOL) and improve sleep quality. A total of 11 young healthy/normal sleeper males challenged to go to bed (lights-off) 2 h earlier than usual were subjected in a randomised order to non-consecutive treatment and control night-time sleep sessions. The treatment night entailed activation of a dual-temperature zone mattress with a cooler centre and warmer periphery plus STS pillow that applied mild heating to the cervical spinal skin for 30 min after lights-off for sleep. During the first 30 min after lights-off, GSBF (mean [standard error (SE)] Δ = 49.77 [19.13] perfusion units, p = 0.013) and DPG (mean [SE] Δ = 2.05 [0.62] °C, p = 0.005) were significantly higher and CBT (mean [SE] Δ = -0.15 [0.07] °C, p = 0.029) was significantly lower in the treatment than control night, while there was no significant difference in these variables during the 45 min prior to lights-off (baseline). Moreover, SOL was significantly reduced (mean [SE] Δ = -48.6 [23.4] min, p = 0.032) and subjective sleep quality significantly better (p 0.001) in the treatment than control night. In conclusion, the novel sleep facilitating system comprised of the STS pillow plus dual-temperature zone mattress induced earlier increase in GSBF and DPG and earlier decline in CBT. This resulted in statistically significant shortened SOL and improved overall sleep quality, thereby reducing sleep pressure of Process S, even under the challenging investigative protocol requiring participants to go to sleep 2 h earlier than customary.
تدمد: 1365-2869
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::e1c9fb2c8ea725a07b6a79f450bd0520
https://pubmed.ncbi.nlm.nih.gov/35852479
حقوق: CLOSED
رقم الأكسشن: edsair.doi.dedup.....e1c9fb2c8ea725a07b6a79f450bd0520
قاعدة البيانات: OpenAIRE