Effect of dental implantation on the hard and soft tissues around the adjacent natural teeth

التفاصيل البيبلوغرافية
العنوان: Effect of dental implantation on the hard and soft tissues around the adjacent natural teeth
المؤلفون: Javad Faradmal, Seyed Reza Arabi, Hanif Allahbakhshi, Sara Khazaei, Samaneh Abbasi, Arash Shishehian, Banafsheh Poormoradi, Farnoush Fotovat
المصدر: Dental and Medical Problems. 56:331-336
بيانات النشر: Wroclaw Medical University, 2019.
سنة النشر: 2019
مصطلحات موضوعية: Male, Crowns, medicine.diagnostic_test, business.industry, Periapical radiography, medicine.medical_treatment, Dentistry, Soft tissue, Physical examination, General Medicine, Esthetics, Dental, Confidence interval, Cohort Studies, Dental Implantation, stomatognathic diseases, Cementoenamel junction, stomatognathic system, medicine, Humans, Female, Implant, Dental papilla, business, Dental implant, General Dentistry
الوصف: BACKGROUND Dental implantation has become widespread for esthetic and functional rehabilitation following single tooth loss as a preferred alternative to conventional tooth-supported restorations. The main advantage of dental implant placement is that it does not require the preparation of the adjacent sound teeth. OBJECTIVES The aim of this cohort study was to assess the effect of dental implantation on the hard and soft tissues around the adjacent natural teeth. MATERIAL AND METHODS In this historical cohort, 34 'connect-type' TBR® implants (bone level), 4 mm in diameter, were submerged in the intact bone of 22 patients (7 males and 15 females). The intraoral and extraoral clinical examination as well as periapical radiography were carried out preoperatively or right after surgery (baseline), at 3 months postoperatively (the time of prosthetic delivery), and at 3 and 6 months after prosthetic delivery. The data was analyzed using the Friedman test (due to the non-normal distribution of the data). In case of presence of a significant difference, pairwise comparisons were performed using the post-hoc Wilcoxon test with the Bonferroni correction. All statistical analyses were performed with a 95% confidence interval (CI) using the SPSS for Windows, v. 16.0 software. The p‑value
تدمد: 2300-9020
1644-387X
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::e2cd7ff982b2d7fda266fd808a7feb19
https://doi.org/10.17219/dmp/110714
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....e2cd7ff982b2d7fda266fd808a7feb19
قاعدة البيانات: OpenAIRE