Modification of Wright's technique for placement of bilateral crossing C2 translaminar screws: technical note

التفاصيل البيبلوغرافية
العنوان: Modification of Wright's technique for placement of bilateral crossing C2 translaminar screws: technical note
المؤلفون: Barth A. Green, Allan D. Levi, Andrew Jea, Steve Vanni, Rishi N. Sheth
المصدر: The Spine Journal. 8:656-660
بيانات النشر: Elsevier BV, 2008.
سنة النشر: 2008
مصطلحات موضوعية: Adult, Joint Instability, Male, musculoskeletal diseases, medicine.medical_specialty, Adolescent, medicine.medical_treatment, Vertebral artery, Radiography, Bone Screws, Fixation (surgical), medicine.artery, medicine, Humans, Orthopedics and Sports Medicine, Spinal canal, Aged, Retrospective Studies, business.industry, Atlanto-axial joint, Technical note, Middle Aged, Surgery, Spinal Fusion, Treatment Outcome, medicine.anatomical_structure, Atlanto-Axial Joint, Spinal fusion, Cervical Vertebrae, Female, Neurology (clinical), business, Cervical vertebrae
الوصف: Background context Several relatively new screw techniques have been described that rigidly capture the posterior elements of C2. The previously described procedures of axis fixation are technically demanding and place the vertebral artery at some risk. A novel and less technically demanding technique of obtaining C-2 translaminar screws has been recently described. Although the risk of vertebral artery injury has been essentially eliminated, the authors recognize that neurologic injury from breakthrough of the inner cortex of the lamina by the drill or screw is still a possibility. Purpose Describe and illustrate a modified C2 translaminar technique and review the results of patients who have undergone the surgery. The current modification of the C2 translaminar screw technique was designed to reduce the risk of inadvertent screw placement within the spinal canal. Study design/setting A techniques paper combined with a retrospective clinical review of patients undergoing the surgery. Patient sample Patients undergoing posterior instrumented fusion surgery of the cervical spine, which incorporates C2 posterior elements using the translaminar technique. Outcome measures Radiographic analysis of the fusion construct incorporating the C2 translaminar screws. Methods We have modified the previously described technique of C-2 translaminar screw placement with the addition of “exit” cortical windows to assure bicortical, intralaminar screw placement. Results The results of the first six patients with an average follow-up of 12 months demonstrated this method to be safe and effective in fixating the axis. Conclusions We have made a simple modification of Wright's elegant technique with the addition of “exit” windows at the facet-laminar junctions. This gives us the assurance that the C2 screw has not entered the spinal canal by directly visualizing the tip of the screw exiting the outer cortices of the lamina before leaving the operating room.
تدمد: 1529-9430
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::eede37dd5e4edab6c5e641e16e7a7ab6
https://doi.org/10.1016/j.spinee.2007.06.008
حقوق: CLOSED
رقم الأكسشن: edsair.doi.dedup.....eede37dd5e4edab6c5e641e16e7a7ab6
قاعدة البيانات: OpenAIRE