Impact of an abbreviated protocol for breast MRI in diagnostic accuracy

التفاصيل البيبلوغرافية
العنوان: Impact of an abbreviated protocol for breast MRI in diagnostic accuracy
المؤلفون: Julia Salleron, Guillaume Oldrini, Frédéric Marchal, Philippe Henrot, Imad Derraz
المصدر: Diagnostic and Interventional Radiology. 24:12-16
بيانات النشر: Galenos Yayinevi, 2018.
سنة النشر: 2018
مصطلحات موضوعية: Adult, Breast imaging, Intraclass correlation, Breast surgery, medicine.medical_treatment, Concordance, Breast Neoplasms, Diagnostic accuracy, Breast magnetic resonance imaging, Sensitivity and Specificity, 030218 nuclear medicine & medical imaging, 03 medical and health sciences, 0302 clinical medicine, Image Processing, Computer-Assisted, medicine, Humans, Breast MRI, Radiology, Nuclear Medicine and imaging, Breast, Aged, Retrospective Studies, Protocol (science), medicine.diagnostic_test, business.industry, Breast Imaging, Reproducibility of Results, Middle Aged, Magnetic Resonance Imaging, 030220 oncology & carcinogenesis, Female, Cardiology and Cardiovascular Medicine, business, Nuclear medicine
الوصف: PURPOSE We aimed to compare the diagnostic accuracy and interpretation time of an abbreviated protocol relative to the complete protocol of breast magnetic resonance imaging (MRI) with the use of breast imaging reporting and data system (BI-RADS). Between-reader and between-protocol variability for BI-RADS classification and influence of reader expertise on diagnostic accuracies were also evaluated. METHODS We conducted a retrospective reader study in 90 women who underwent breast MRI: 30 benign examinations (graded as American College of Radiology [ACR] 1 or 2), 30 examinations graded as ACR 3 and 30 examinations requiring a histologic proof (graded as ACR 4 or 5). Two radiologists independently reviewed the protocols. The reference standard was 24 months of imaging follow-up (66.6%, n=60), percutaneous biopsy at the 12th month imaging follow-up (5.5%, n=5), and breast surgery (27.9%, n=25). Analysis was done on a per-breast basis. There were 26 cancers in 168 breasts (15.1%) RESULTS: Interpretation time was higher for the complete protocol (mean difference: 84 s, 95% CI [67;101] for senior and 83 s, 95% CI [70;95] for junior reader; P < 0.001). The reliability of BI-RADS classification between both protocols was very good with intraclass correlation coefficient of 0.89 for junior reader and 0.98 for senior reader; the inter-reader reliability was 0.94 and 0.90 for the complete and abbreviated protocols, respectively. For senior reader, the abbreviated and complete protocols yielded 95.1% and 94.4% specificity and 100% sensitivity. CONCLUSION Our data provide corroborating evidence that abbreviated protocols decrease interpretation time without compromising sensitivity or specificity. There was a high level of concordance between the abbreviated and complete protocols and between the two readers.
تدمد: 1305-3612
1305-3825
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::f06208b824f6348ac21d2549dd1b2059
https://doi.org/10.5152/dir.2018.16609
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....f06208b824f6348ac21d2549dd1b2059