Leadless transcatheter pacemaker: Indications, implantation technique and peri-procedural patient management in the Italian clinical practice

التفاصيل البيبلوغرافية
العنوان: Leadless transcatheter pacemaker: Indications, implantation technique and peri-procedural patient management in the Italian clinical practice
المؤلفون: Pietro Palmisano, Saverio Iacopino, Stefano De Vivo, Carlo D'Agostino, Luca Tomasi, Umberto Startari, Matteo Ziacchi, Ennio Carmine Luigi Pisanò, Vincenzo Ezio Santobuono, Vincenzo Paolo Caccavo, Giuseppe Sgarito, Mariano Rillo, Antonino Nicosia, Giulio Zucchelli
المصدر: International journal of cardiology. 365
سنة النشر: 2022
مصطلحات موضوعية: Male, Pacemaker, Artificial, Time Factors, Treatment Outcome, Humans, Female, Equipment Design, Prospective Studies, Cardiology and Cardiovascular Medicine, Pericardial Effusion
الوصف: Safety and efficacy of leadless pacemakers (L-PM) have been demonstrated in multiple clinical trials, but real-world data on patient selection, implantation technique, and peri-procedural patient management in a clinical practice setting are lacking.Consecutive patients undergoing L-PM implantation in 14 Italian centers were followed in a prospective, multicentre, observational project. Data on baseline patient characteristics, clinical indications, implantation procedure, and peri-procedural patient management were collected. The rate and nature of device-related complications were also recorded.A total of 782 L-PM patients (68.4% male, 75.6 ± 12.4 years) were included in the analysis. The main patients-related reason leading to the choice of implanting a L-PM rather than a conventional PM was the high-risk of device infection (29.5% of cases). The implantation success rate was 99.2%. The median duration of the procedure was 46 min. In 90% of patients the device was implanted in the septum. Of patients on oral anticoagulant therapy (OAT) (n = 498) the implantation procedure was performed without interrupting (17.5%) or transiently interrupting OAT without heparin bridging (60.6%). During a median follow-up of 20 months major device-related complications occurred in 7 patients (0.9%): vascular access-site complications in 3 patients, device malfunction in 2 patients, pericardial effusion/cardiac tamponade in one patient, device migration in one patient.In the real world setting of Italian clinical practice L-PM is often reserved for patients at high-risk of infection. The implantation success rate was very high and the risk of major complications was low. Peri-procedural management of OAT was consistent with available scientific evidence.
تدمد: 1874-1754
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::f07a8b98c4b870b325695b6778a9a1a9
https://pubmed.ncbi.nlm.nih.gov/35907505
حقوق: CLOSED
رقم الأكسشن: edsair.doi.dedup.....f07a8b98c4b870b325695b6778a9a1a9
قاعدة البيانات: OpenAIRE