Radiomics based on diffusion-weighted imaging for differentiation between focal-type autoimmune pancreatitis and pancreatic carcinoma

التفاصيل البيبلوغرافية
العنوان: Radiomics based on diffusion-weighted imaging for differentiation between focal-type autoimmune pancreatitis and pancreatic carcinoma
المؤلفون: Megumi Shiraishi, Takao Igarashi, Fujioka Hiroaki, Rika Oe, Kazuyoshi Ohki, Hiroya Ojiri
المصدر: The British Journal of Radiology. 95
بيانات النشر: British Institute of Radiology, 2022.
سنة النشر: 2022
مصطلحات موضوعية: Diagnosis, Differential, Pancreatic Neoplasms, Diffusion Magnetic Resonance Imaging, ROC Curve, Autoimmune Pancreatitis, Humans, Reproducibility of Results, Radiology, Nuclear Medicine and imaging, General Medicine, Retrospective Studies, Carcinoma, Pancreatic Ductal
الوصف: Objective: To evaluate the parameters of support vector machine (SVM) using imaging data generated from the apparent diffusion coefficient (ADC) to differentiate between focal-type autoimmune pancreatitis (f-AIP) and pancreatic ductal adenocarcinoma (PDAC) when using SVM based on diffusion-weighted imaging. Methods: The 2D-ADCmean and texture parameters (16 texture features × [non-filter+17 filters]) were retrospectively segmented by 2 readers in 28 patients with f-AIP and 77 patients with pathologically proven PDAC. The diagnostic accuracy of the SVM model was evaluated by receiver operating characteristic curve analysis and calculation of the area under the curve (AUC). Interreader reliability was assessed by intraclass correlation coefficient (ICC). Results: The 2D-ADCmean and 3D-ADCmean were significantly lower in cases of f-AIP (1.10–1.15 × 10–3 mm2/s and 1.21–1.23× 10–3 mm2/s, respectively) vs PDAC (1.29–1.33 × 10–3 mm2/s and 1.41–1.43 × 10–3 mm2/s, respectively), with excellent and good interreader reliability, respectively (ICC = 0.909 and 0.891, respectively). Among the texture parameters, energy with exponential filtering yielded the highest AUC (Reader 1: 74.7%, Reader 2: 81.5%), with fair interreader reliability (ICC = 0.707). The non-linear SVM, a combination of 2D-ADCmean, object volume and exponential-energy showed an AUC value of 96.2% in the testing cohorts. Conclusion: Our results suggest that non-linear SVM using a combination of 2D-ADCmean, object volume, and exponential-energy may assist in differentiating f-AIP from PDAC. Advances in knowledge: The radiomics based on an apparent diffusion coefficient value may assist in differentiating f-AIP from PDAC.
تدمد: 1748-880X
0007-1285
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::f1645e2a6673857b13f30922cdf1ac09
https://doi.org/10.1259/bjr.20210456
رقم الأكسشن: edsair.doi.dedup.....f1645e2a6673857b13f30922cdf1ac09
قاعدة البيانات: OpenAIRE