Hyris bCUBE SARS-CoV-2 rapid molecular saliva testing: a POCT innovation on its way

التفاصيل البيبلوغرافية
العنوان: Hyris bCUBE SARS-CoV-2 rapid molecular saliva testing: a POCT innovation on its way
المؤلفون: Andrea Padoan, Chiara Cosma, Ada Aita, Filippo Navaglia, Daniela Basso, Gianfranco Giannella, Mario Plebani
بيانات النشر: WALTER DE GRUYTER GMBH, 2022.
سنة النشر: 2022
مصطلحات موضوعية: saliva, SARS-CoV-2, Biochemistry (medical), Clinical Biochemistry, COVID-19, General Medicine, Sensitivity and Specificity, rapid molecular testing, assay comparison, pooling strategies, Point-of-Care Testing, Humans, RNA, Viral
الوصف: Objectives The reliable identification of individuals with SARS-CoV-2 infection is the cornerstone for containing viral spread. Rapid molecular point-of-care testing (POCT) of saliva might reduce analysis time, thus increasing the efficacy of contact tracing. In this study, a new POCT RT-PCR assay for the detection of SARS-CoV-2 RNA in saliva was evaluated and compared with an already validated CE-IVD method. Methods An evaluation was made of 160 left-over salivary samples (27 frozen, kept at −80 °C and 133 fresh), collected using Salivette (Sarstedt, Germany). Samples were analyzed by TaqPath COVID-19 CE-IVD RT-PCR kit, QuantStudio5 Real-Time (Applied Biosystems, USA) (TaqPath) and bKIT Virus Finder COVID-19 Saliva (Hyris Global Diagnostics, Italy). Performances of three- and fivefold pooling strategies were also evaluated. Blood assay interference in saliva was also tested with Hyris. Results On using TaqPath, SARS-CoV-2 positivity was detected in 35 samples. Another 10 positive samples were artificially-generated by blind mixing of positive with negative samples. Hyris positive and negative percentages of agreement were 97.6 (95% CI: 87.2–99.9%) and 100 (95% CI: 97.0–100%), respectively. Seventeen positive pools, evaluated for threefold strategy, were all correctly determined by both systems. For the 5-pool strategy, 94.7% (18/19) of samples resulted positive with the Hyris system, and 100% with TaqPath. The presence of 1% of blood (v/v) in saliva did not interfere with the accuracy of Hyris assay. Conclusions The sensitivity and specificity of the bKIT Virus Finder COVID-19 Saliva were optimal with respect to TaqPath. In view of the safe and straightforward pre-analytical procedure involved, and the small size of the Hyris bCube, the Hyris system can be used for POCT.
اللغة: English
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::f4d0c7e8b0cb70f4945396d04fbf2cab
http://hdl.handle.net/11577/3413392
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....f4d0c7e8b0cb70f4945396d04fbf2cab
قاعدة البيانات: OpenAIRE