Comparison of various tendon repair techniques in extansor zone 3 injuries: an experimental biomechanical cadaver study

التفاصيل البيبلوغرافية
العنوان: Comparison of various tendon repair techniques in extansor zone 3 injuries: an experimental biomechanical cadaver study
المؤلفون: Murat Kayalar, Fatma Kübra Erbay Elibol, Hacı Bayram Tosun, Abuzer Uludag, Teyfik Demir, Güneş Aytaç, Suat Çelik, Muzaffer Sindel, Sancar Serbest
المساهمون: TOBB ETU, Faculty of Engineering, Department of Mechanical Engineering, TOBB ETÜ, Mühendislik Fakültesi, Makine Mühendisliği Bölümü, Demir, Teyfik, Kırıkkale Üniversitesi, KKÜ
بيانات النشر: Springer, 2020.
سنة النشر: 2020
مصطلحات موضوعية: Ultimate load, medicine.medical_specialty, Biomechanic, Fingers, Tendons, 03 medical and health sciences, 0302 clinical medicine, Hand injury, Suture (anatomy), Zone 3, Cadaver, Tendon Injuries, Finger Injuries, Tendon repair, medicine, Humans, Orthopedics and Sports Medicine, Suture, Orthodontics, 030222 orthopedics, business.industry, Suture Techniques, Stiffness, 030229 sport sciences, General Medicine, medicine.disease, Tendon, Biomechanical Phenomena, medicine.anatomical_structure, Orthopedic surgery, Tendon zone, Surgery, medicine.symptom, Extansor, business
الوصف: aytac, gunes/0000-0003-4902-2844 WOS:000522643800019 PubMed: 32130480 Purpose To compare five different repair techniques for extensor tendon zone III modified Kessler (MK), double-modified Kessler (DMK), modified Kessler epitendinous (MKE), double-modified Kessler epitendinous (DMKE), and running-interlocking horizontal mattress (RIHM) in terms of shortening, stiffness, gap formation, and ultimate load to failure. Methods A total of 35 human cadaver fingers were randomly assigned to five suture techniques with 7 fingers each and were tested under dynamic and static loading conditions. Results DMK was found to be superior over MK in terms of ultimate load to failure (36 N vs. 24 N, respectively), shortening (1.75 vs. 2.20 mm, respectively) and gap formation. However, these two methods had similar characteristics in terms of stiffness. The addition of epitendinous sutures to the repair methods resulted in approximately 40% increase in ultimate load to failure, whereas epitendinous sutures had no effect on shortening. DMKE was found to be superior over MKE in terms of shortening (1.77 vs. 2.22 mm, respectively). However, these two methods had similar characteristics in terms of mean ultimate load to failure and stiffness. RIHM was found to be superior over the other four methods in terms of ultimate load to failure (89 N), stiffness, and shortening (0.75 mm). Conclusion RIHM was found to be stronger and more durable for extensor tendon zone III than the other techniques in terms of ultimate load to failure and stiffness.
وصف الملف: application/pdf
اللغة: English
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::fbd548db6d383947b2c08ca095ab2792
http://hdl.handle.net/20.500.11851/3821
حقوق: CLOSED
رقم الأكسشن: edsair.doi.dedup.....fbd548db6d383947b2c08ca095ab2792
قاعدة البيانات: OpenAIRE