Diagnostic Performance of Dynamic Whole-Body Patlak [18F]FDG-PET/CT in Patients with Indeterminate Lung Lesions and Lymph Nodes

التفاصيل البيبلوغرافية
العنوان: Diagnostic Performance of Dynamic Whole-Body Patlak [18F]FDG-PET/CT in Patients with Indeterminate Lung Lesions and Lymph Nodes
المؤلفون: Fougère, Matthias Weissinger, Max Atmanspacher, Werner Spengler, Ferdinand Seith, Sebastian Von Beschwitz, Helmut Dittmann, Lars Zender, Anne M. Smith, Michael E. Casey, Konstantin Nikolaou, Salvador Castaneda-Vega, Christian la
المصدر: Journal of Clinical Medicine; Volume 12; Issue 12; Pages: 3942
بيانات النشر: Multidisciplinary Digital Publishing Institute, 2023.
سنة النشر: 2023
مصطلحات موضوعية: whole-body, dynamic PET, parametric FDG, Patlak, FDG, PET/CT
الوصف: Background: Static [18F]FDG-PET/CT is the imaging method of choice for the evaluation of indeterminate lung lesions and NSCLC staging; however, histological confirmation of PET-positive lesions is needed in most cases due to its limited specificity. Therefore, we aimed to evaluate the diagnostic performance of additional dynamic whole-body PET. Methods: A total of 34 consecutive patients with indeterminate pulmonary lesions were enrolled in this prospective trial. All patients underwent static (60 min p.i.) and dynamic (0–60 min p.i.) whole-body [18F]FDG-PET/CT (300 MBq) using the multi-bed-multi-timepoint technique (Siemens mCT FlowMotion). Histology and follow-up served as ground truth. Kinetic modeling factors were calculated using a two-compartment linear Patlak model (FDG influx rate constant = Ki, metabolic rate = MR-FDG, distribution volume = DV-FDG) and compared to SUV using ROC analysis. Results: MR-FDGmean provided the best discriminatory power between benign and malignant lung lesions with an AUC of 0.887. The AUC of DV-FDGmean (0.818) and SUVmean (0.827) was non-significantly lower. For LNM, the AUCs for MR-FDGmean (0.987) and SUVmean (0.993) were comparable. Moreover, the DV-FDGmean in liver metastases was three times higher than in bone or lung metastases. Conclusions: Metabolic rate quantification was shown to be a reliable method to detect malignant lung tumors, LNM, and distant metastases at least as accurately as the established SUV or dual-time-point PET scans.
وصف الملف: application/pdf
اللغة: English
تدمد: 2077-0383
DOI: 10.3390/jcm12123942
URL الوصول: https://explore.openaire.eu/search/publication?articleId=multidiscipl::acb2de88c68f4b757508a7e3f74ddc10
حقوق: OPEN
رقم الأكسشن: edsair.multidiscipl..acb2de88c68f4b757508a7e3f74ddc10
قاعدة البيانات: OpenAIRE
الوصف
تدمد:20770383
DOI:10.3390/jcm12123942