Experiment for transient effects of sudden catastrophic loss of vacuum on a scaled superconducting radio frequency cryomodule

التفاصيل البيبلوغرافية
العنوان: Experiment for transient effects of sudden catastrophic loss of vacuum on a scaled superconducting radio frequency cryomodule
المؤلفون: Dalesandro, A., Theilacker, J., Van Sciver, S. W.
المصدر: AIP Conf.Proc. 1434 (2011) 1567-1574
سنة النشر: 2012
المجموعة: Physics (Other)
مصطلحات موضوعية: Physics - Accelerator Physics, Physics - Instrumentation and Detectors
الوصف: Safe operation of superconducting radio frequency (SRF) cavities require design consideration of a sudden catastrophic loss of vacuum (SCLV) adjacent with liquid helium (LHe) vessels and subsequent dangers. An experiment is discussed to test the longitudinal effects of SCLV along the beam line of a string of scaled SRF cavities. Each scaled cavity includes one segment of beam tube within a LHe vessel containing 2 K saturated LHe, and a riser pipe connecting the LHe vessel to a common gas header. At the beam tube inlet is a fast acting solenoid valve to simulate SCLV and a high/low range orifice plate flow-meter to measure air influx to the cavity. The gas header exit also has an orifice plate flow-meter to measure helium venting the system at the relief pressure of 0.4 MPa. Each cavity is instrumented with Validyne pressure transducers and Cernox thermometers. The purpose of this experiment is to quantify the time required to spoil the beam vacuum and the effects of transient heat and mass transfer on the helium system. Heat transfer data is expected to reveal a longitudinal effect due to the geometry of the experiment. Details of the experimental design criteria and objectives are presented.
Comment: 8 pp. Cryogenic Engineering Conference and International Cryogenic Materials Conference CEC-ICMC. 13-17 June 2011. Spokane, Washington
نوع الوثيقة: Working Paper
DOI: 10.1063/1.4707087
URL الوصول: http://arxiv.org/abs/1209.4615
رقم الأكسشن: edsarx.1209.4615
قاعدة البيانات: arXiv