Commissioning experience and beam physics measurements at the SwissFEL Injector Test Facility

التفاصيل البيبلوغرافية
العنوان: Commissioning experience and beam physics measurements at the SwissFEL Injector Test Facility
المؤلفون: Schietinger, T., Pedrozzi, M., Aiba, M., Arsov, V., Bettoni, S., Beutner, B., Calvi, M., Craievich, P., Dehler, M., Frei, F., Ganter, R., Hauri, C. P., Ischebeck, R., Ivanisenko, Y., Janousch, M., Kaiser, M., Keil, B., Löhl, F., Orlandi, G. L., Loch, C. Ozkan, Peier, P., Prat, E., Raguin, J. -Y., Reiche, S., Schilcher, T., Wiegand, P., Zimoch, E., Anicic, D., Armstrong, D., Baldinger, M., Baldinger, R., Bertrand, A., Bitterli, K., Bopp, M., Brands, H., Braun, H. H., Brönnimann, M., Brunnenkant, I., Chevtsov, P., Chrin, J., Citterio, A., Divall, M. Csatari, Dach, M., Dax, A., Ditter, R., Divall, E., Falone, A., Fitze, H., Geiselhart, C., Guetg, M. W., Hämmerli, F., Hauff, A., Heiniger, M., Higgs, C., Hugentobler, W., Hunziker, S., Janser, G., Kalantari, B., Kalt, R., Kim, Y., Koprek, W., Korhonen, T., Krempaska, R., Laznovsky, M., Lehner, S., Pimpec, F. Le, Lippuner, T., Lutz, H., Mair, S., Marcellini, F., Marinkovic, G., Menzel, R., Milas, N., Pal, T., Pollet, P., Portmann, W., Rezaeizadeh, A., Ritt, S., Rohrer, M., Schär, M., Schebacher, L., Scherrer, St., Schmidt, V. Schlott T., Schulz, L., Smit, B., Stadler, M., Steffen, B., Stingelin, L., Sturzenegger, W., Treyer, D. M., Trisorio, A., Tron, W., Vicario, C., Zennaro, R., Zimoch, D.
المصدر: Phys. Rev. ST Accel. Beams 19, 100702 (2016)
سنة النشر: 2016
المجموعة: Physics (Other)
مصطلحات موضوعية: Physics - Accelerator Physics
الوصف: The SwissFEL Injector Test Facility operated at the Paul Scherrer Institute between 2010 and 2014, serving as a pilot plant and testbed for the development and realization of SwissFEL, the X-ray Free-Electron Laser facility under construction at the same institute. The test facility consisted of a laser-driven rf electron gun followed by an S-band booster linac, a magnetic bunch compression chicane and a diagnostic section including a transverse deflecting rf cavity. It delivered electron bunches of up to 200 pC charge and up to 250 MeV beam energy at a repetition rate of 10 Hz. The measurements performed at the test facility not only demonstrated the beam parameters required to drive the first stage of an FEL facility, but also led to significant advances in instrumentation technologies, beam characterization methods and the generation, transport and compression of ultra-low-emittance beams. We give a comprehensive overview of the commissioning experience of the principal subsystems and the beam physics measurements performed during the operation of the test facility, including the results of the test of an in-vacuum undulator prototype generating radiation in the vacuum ultraviolet and optical range.
Comment: 60 pages, 70 figures; final version as published, except with table of contents and Fig. 68 in full resolution
نوع الوثيقة: Working Paper
DOI: 10.1103/PhysRevAccelBeams.19.100702
URL الوصول: http://arxiv.org/abs/1606.02586
رقم الأكسشن: edsarx.1606.02586
قاعدة البيانات: arXiv
الوصف
DOI:10.1103/PhysRevAccelBeams.19.100702