Diamond Detectors for the TOTEM Timing Upgrade

التفاصيل البيبلوغرافية
العنوان: Diamond Detectors for the TOTEM Timing Upgrade
المؤلفون: TOTEM Collaboration, Antchev, G., Aspell, P., Atanassov, I., Avati, V., Baechler, J., Berardi, V., Berretti, M., Bossini, E., Bottigli, U., Bozzo, M., Broulím, P., Buzzo, A., Cafagna, F. S., Catanesi, M. G., Csanád, M., Csörgő, T., Deile, M., De Leonardis, F., D'Orazio, A., Doubek, M., Eggert, K., Eremin, V., Ferro, F., Fiergolski, A., Garcia, F., Georgiev, V., Giani, S., Grzanka, L., Guaragnella, C., Hammerbauer, J., Heino, J., Karev, A., Kašpar, J., Kopal, J., Kundrát, V., Lami, S., Latino, G., Lauhakangas, R., Linhart, R., Lokajíček, M. V., Losurdo, L., Vetere, M. Lo, Rodríguez, F. Lucas, Lucsányi, D., Macrí, M., Mercadante, A., Minafra, N., Minutoli, S., Naaranoja, T., Nemes, F., Niewiadomski, H., Novák, T., Oliveri, E., Oljemark, F., Oriunno, M., Österberg, K., Palazzi, P., Paločko, L., Passaro, V., Peroutka, Z., Petruzzelli, V., Politi, T., Procházka, J., Prudenzano, F., Quinto, M., Radermacher, E., Radicioni, E., Ravotti, F., Robutti, E., Royon, C., Ruggiero, G., Saarikko, H., Scribano, A., Smajek, J., Snoeys, W., Sziklai, J., Taylor, C., Turini, N., Vacek, V., Welti, J., Wyszkowski, P., Zielinski, K.
المصدر: JINST 12 (2017) no.03, P03007
سنة النشر: 2017
المجموعة: High Energy Physics - Experiment
Physics (Other)
مصطلحات موضوعية: Physics - Instrumentation and Detectors, High Energy Physics - Experiment
الوصف: This paper describes the design and the performance of the timing detector developed by the TOTEM Collaboration for the Roman Pots (RPs) to measure the Time-Of-Flight (TOF) of the protons produced in central diffractive interactions at the LHC. The measurement of the TOF of the protons allows the determination of the longitudinal position of the proton interaction vertex and its association with one of the vertices reconstructed by the CMS detectors. The TOF detector is based on single crystal Chemical Vapor Deposition (scCVD) diamond plates and is designed to measure the protons TOF with about 50 ps time precision. This upgrade to the TOTEM apparatus will be used in the LHC run 2 and will tag the central diffractive events up to an interaction pileup of about 1. A dedicated fast and low noise electronics for the signal amplification has been developed. The digitization of the diamond signal is performed by sampling the waveform. After introducing the physics studies that will most profit from the addition of these new detectors, we discuss in detail the optimization and the performance of the first TOF detector installed in the LHC in November 2015.
Comment: 26 pages, 18 figures, 2 tables, submitted for publication to JINST
نوع الوثيقة: Working Paper
DOI: 10.1088/1748-0221/12/03/P03007
URL الوصول: http://arxiv.org/abs/1701.05227
رقم الأكسشن: edsarx.1701.05227
قاعدة البيانات: arXiv
الوصف
DOI:10.1088/1748-0221/12/03/P03007