تقرير
Development of a $^{127}$Xe calibration source for nEXO
العنوان: | Development of a $^{127}$Xe calibration source for nEXO |
---|---|
المؤلفون: | Lenardo, B. G., Hardy, C. A., Tsang, R. H. M., Ondze, J. C. Nzobadila, Piepke, A., Triambak, S., Jamil, A., Adhikari, G., Kharusi, S. Al, Angelico, E., Arnquist, I. J., Belov, V., Bernard, E. P., Bhat, A., Bhatta, T., Bolotnikov, A., Breur, P. A., Brodsky, J. P., Brown, E., Brunner, T., Caden, E., Cao, G. F., Cao, L., Chana, B., Charlebois, S. A., Chernyak, D., Chiu, M., Cohen, J. R., Collister, R., Dalmasson, J., Daniels, T., Darroch, L., DeVoe, R., di Vacri, M. L., Ding, Y. Y., Dolinski, M. J., Echevers, J., Eckert, B., Elbeltagi, M., Fabris, L., Fairbank, D., Fairbank, W., Farine, J., Fu, Y. S., Gallina, G., Gautam, P., Giacomini, G., Gillis, W., Gingras, C., Gornea, R., Gratta, G., Harouaka, K., Heffner, M., Hein, E., Hößl, J., House, A., Iverson, A., Jiang, X. S., Karelin, A., Kaufman, L. J., Krücken, R., Kuchenkov, A., Kumar, K. S., Larson, A., Leach, K. G., Leonard, D. S., Li, G., Li, S., Li, Z., Licciardi, C., Lindsay, R., MacLellan, R., Masbou, J., McMichael, K., Peregrina, M. Medina, Mong, B., Moore, D. C., Murray, K., Nattress, J., Natzke, C. R., Ngwadla, X. E., Ni, K., Ning, Z., Orrell, J. L., Ortega, G. S., Ostrovskiy, I., Overman, C. T., Perna, A., Franco, T. Pinto, Pocar, A., Pratte, J. F., Priel, N., Raguzin, E., Ramonnye, G. J., Rasiwala, H., Raymond, K., Richardson, G., Richman, M., Ringuette, J., Rowson, P. C., Saldanha, R., Sangiorgio, S., Shang, X., Soma, A. K., Spadoni, F., Stekhanov, V., Sun, X. L., Thibado, S., Tidball, A., Todd, J., Totev, T., Tyuka, O. A., Vachon, F., Veeraraghavan, V., Viel, S., Wamba, K., Wang, Y., Wang, Q., Wei, W., Wen, L. J., Wichoski, U., Wilde, S., Wu, W. H., Yan, W., Yang, L., Zeldovich, O., Zhao, J., Ziegler, T. |
سنة النشر: | 2022 |
المجموعة: | Nuclear Experiment Physics (Other) |
مصطلحات موضوعية: | Physics - Instrumentation and Detectors, Nuclear Experiment |
الوصف: | We study a possible calibration technique for the nEXO experiment using a $^{127}$Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay ($0\nu\beta\beta$) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in $^{136}$Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of $^{127}$Xe and its small $Q$-value compared to that of $^{136}$Xe $0\nu\beta\beta$ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC. Comment: 24 pages, 16 figures |
نوع الوثيقة: | Working Paper |
DOI: | 10.1088/1748-0221/17/07/P07028 |
URL الوصول: | http://arxiv.org/abs/2201.04681 |
رقم الأكسشن: | edsarx.2201.04681 |
قاعدة البيانات: | arXiv |
DOI: | 10.1088/1748-0221/17/07/P07028 |
---|